The effect of different flushing methods in a short peripheral catheter

Bibliographic Details
Title: The effect of different flushing methods in a short peripheral catheter
Authors: Tong, Cuiling, Peng, Xiaochun, Hu, Hong, Wang, Zongwen, Zhou, Hong
Source: Acta Cirúrgica Brasileira. January 2019 34(8)
Publisher Information: Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, 2019.
Publication Year: 2019
Subject Terms: Catheterization, Peripheral, Blood Vessels, Rabbits
More Details: Purpose To develop a rabbit model of a short peripheral catheter (SPC) and to observe the effects of different flushing methods on blood vessels. Methods Thirty rabbits were randomly divided into three groups (A, B, and C), with ten rabbits per group. In group A, we used pulsed flush; in group B, we used uniform flush; and no treatment was used in group C. Results We observed that a uniform flush reduced blockage, phlebitis, and exudation compared to a pulsed flush by visual observation. The histopathological examination found that the morphological changes in group A were more severe than in group B and C related to loss of venous endothelial cells, inflammatory cell infiltration, edema, epidermal and chondrocyte degeneration, except for the thrombosis on group B that was more serious than in group A, especially in the distal side of puncture points. The distal region of groups A and B had more inflammatory cell infiltration than the proximal region. Thrombosis was more severe in the distal region than in the proximal region in group B. Conclusions The uniform flush produced less damage to the vascular endothelium and surrounding tissues and was superior to the pulsed flush. However, the uniform flush is prone to thrombosis.
Document Type: article
File Description: text/html
Language: English
ISSN: 0102-8650
DOI: 10.1590/s0102-865020190080000004
Access URL: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502019000800202
Rights: info:eu-repo/semantics/openAccess
Accession Number: edssci.S0102.86502019000800202
Database: SciELO
FullText Text:
  Availability: 0
CustomLinks:
  – Url: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502019000800202#
    Name: EDS - SciELO
    Category: fullText
    Text: Full Text from SciELO
    MouseOverText: Full Text from SciELO
  – Url: https://resolver.ebsco.com/c/xy5jbn/result?sid=EBSCO:edssci&genre=article&issn=01028650&ISBN=&volume=34&issue=8&date=20190101&spage=&pages=&title=Acta Cirúrgica Brasileira&atitle=The%20effect%20of%20different%20flushing%20methods%20in%20a%20short%20peripheral%20catheter&aulast=Tong%2C%20Cuiling&id=DOI:10.1590/s0102-865020190080000004
    Name: Full Text Finder (for New FTF UI) (s8985755)
    Category: fullText
    Text: Find It @ SCU Libraries
    MouseOverText: Find It @ SCU Libraries
Header DbId: edssci
DbLabel: SciELO
An: edssci.S0102.86502019000800202
RelevancyScore: 923
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 922.664306640625
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: The effect of different flushing methods in a short peripheral catheter
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Tong%2C+Cuiling%22">Tong, Cuiling</searchLink><br /><searchLink fieldCode="AR" term="%22Peng%2C+Xiaochun%22">Peng, Xiaochun</searchLink><br /><searchLink fieldCode="AR" term="%22Hu%2C+Hong%22">Hu, Hong</searchLink><br /><searchLink fieldCode="AR" term="%22Wang%2C+Zongwen%22">Wang, Zongwen</searchLink><br /><searchLink fieldCode="AR" term="%22Zhou%2C+Hong%22">Zhou, Hong</searchLink>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <i>Acta Cirúrgica Brasileira</i>. January 2019 34(8)
– Name: Publisher
  Label: Publisher Information
  Group: PubInfo
  Data: Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, 2019.
– Name: DatePubCY
  Label: Publication Year
  Group: Date
  Data: 2019
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Catheterization%2C+Peripheral%22">Catheterization, Peripheral</searchLink><br /><searchLink fieldCode="DE" term="%22Blood+Vessels%22">Blood Vessels</searchLink><br /><searchLink fieldCode="DE" term="%22Rabbits%22">Rabbits</searchLink>
– Name: Abstract
  Label: Description
  Group: Ab
  Data: Purpose To develop a rabbit model of a short peripheral catheter (SPC) and to observe the effects of different flushing methods on blood vessels. Methods Thirty rabbits were randomly divided into three groups (A, B, and C), with ten rabbits per group. In group A, we used pulsed flush; in group B, we used uniform flush; and no treatment was used in group C. Results We observed that a uniform flush reduced blockage, phlebitis, and exudation compared to a pulsed flush by visual observation. The histopathological examination found that the morphological changes in group A were more severe than in group B and C related to loss of venous endothelial cells, inflammatory cell infiltration, edema, epidermal and chondrocyte degeneration, except for the thrombosis on group B that was more serious than in group A, especially in the distal side of puncture points. The distal region of groups A and B had more inflammatory cell infiltration than the proximal region. Thrombosis was more severe in the distal region than in the proximal region in group B. Conclusions The uniform flush produced less damage to the vascular endothelium and surrounding tissues and was superior to the pulsed flush. However, the uniform flush is prone to thrombosis.
– Name: TypeDocument
  Label: Document Type
  Group: TypDoc
  Data: article
– Name: Format
  Label: File Description
  Group: SrcInfo
  Data: text/html
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: ISSN
  Label: ISSN
  Group: ISSN
  Data: 0102-8650
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1590/s0102-865020190080000004
– Name: URL
  Label: Access URL
  Group: URL
  Data: <link linkTarget="URL" linkTerm="http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502019000800202" linkWindow="_blank">http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502019000800202</link>
– Name: Copyright
  Label: Rights
  Group: Cpyrght
  Data: info:eu-repo/semantics/openAccess
– Name: AN
  Label: Accession Number
  Group: ID
  Data: edssci.S0102.86502019000800202
PLink https://login.libproxy.scu.edu/login?url=https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edssci&AN=edssci.S0102.86502019000800202
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1590/s0102-865020190080000004
    Languages:
      – Text: English
    Subjects:
      – SubjectFull: Catheterization, Peripheral
        Type: general
      – SubjectFull: Blood Vessels
        Type: general
      – SubjectFull: Rabbits
        Type: general
    Titles:
      – TitleFull: The effect of different flushing methods in a short peripheral catheter
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Tong, Cuiling
      – PersonEntity:
          Name:
            NameFull: Peng, Xiaochun
      – PersonEntity:
          Name:
            NameFull: Hu, Hong
      – PersonEntity:
          Name:
            NameFull: Wang, Zongwen
      – PersonEntity:
          Name:
            NameFull: Zhou, Hong
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Type: published
              Y: 2019
          Identifiers:
            – Type: issn-print
              Value: 01028650
          Numbering:
            – Type: volume
              Value: 34
            – Type: issue
              Value: 8
          Titles:
            – TitleFull: Acta Cirúrgica Brasileira
              Type: main
ResultId 1