Shot noise limited soft x-ray absorption spectroscopy in solution at a SASE-FEL using a transmission grating beam splitter

Bibliographic Details
Title: Shot noise limited soft x-ray absorption spectroscopy in solution at a SASE-FEL using a transmission grating beam splitter
Authors: Robin Y. Engel, Maria Ekimova, Piter S. Miedema, Carlo Kleine, Jan Ludwig, Miguel Ochmann, Benjamin Grimm-Lebsanft, Rory Ma, Melissa Teubner, Siarhei Dziarzhytski, Günter Brenner, Marie Kristin Czwalinna, Benedikt Rösner, Tae Kyu Kim, Christian David, Sonja Herres-Pawlis, Michael Rübhausen, Erik T. J. Nibbering, Nils Huse, Martin Beye
Source: Structural Dynamics, Vol 8, Iss 1, Pp 014303-014303-7 (2021)
Publisher Information: AIP Publishing LLC and ACA, 2021.
Publication Year: 2021
Collection: LCC:Crystallography
Subject Terms: Crystallography, QD901-999
More Details: X-ray absorption near-edge structure (XANES) spectroscopy provides element specificity and is a powerful experimental method to probe local unoccupied electronic structures. In the soft x-ray regime, it is especially well suited for the study of 3d-metals and light elements such as nitrogen. Recent developments in vacuum-compatible liquid flat jets have facilitated soft x-ray transmission spectroscopy on molecules in solution, providing information on valence charge distributions of heteroatoms and metal centers. Here, we demonstrate XANES spectroscopy of molecules in solution at the nitrogen K-edge, performed at FLASH, the Free-Electron Laser (FEL) in Hamburg. A split-beam referencing scheme optimally characterizes the strong shot-to-shot fluctuations intrinsic to the process of self-amplified spontaneous emission on which most FELs are based. Due to this normalization, a sensitivity of 1% relative transmission change is achieved, limited by fundamental photon shot noise. The effective FEL bandwidth is increased by streaking the electron energy over the FEL pulse train to measure a wider spectral window without changing FEL parameters. We propose modifications to the experimental setup with the potential of improving the instrument sensitivity by two orders of magnitude, thereby exploiting the high peak fluence of FELs to enable unprecedented sensitivity for femtosecond XANES spectroscopy on liquids in the soft x-ray spectral region.
Document Type: article
File Description: electronic resource
Language: English
ISSN: 2329-7778
Relation: https://doaj.org/toc/2329-7778
DOI: 10.1063/4.0000049
Access URL: https://doaj.org/article/feb3d739ad9947ce97291365377f194f
Accession Number: edsdoj.feb3d739ad9947ce97291365377f194f
Database: Directory of Open Access Journals
More Details
ISSN:23297778
DOI:10.1063/4.0000049
Published in:Structural Dynamics
Language:English