Comparison of SMS-EPI and 3D-EPI at 7T in an fMRI localizer study with matched spatiotemporal resolution and homogenized excitation profiles.

Bibliographic Details
Title: Comparison of SMS-EPI and 3D-EPI at 7T in an fMRI localizer study with matched spatiotemporal resolution and homogenized excitation profiles.
Authors: Caroline Le Ster, Antonio Moreno, Franck Mauconduit, Vincent Gras, Ruediger Stirnberg, Benedikt A Poser, Alexandre Vignaud, Evelyn Eger, Stanislas Dehaene, Florent Meyniel, Nicolas Boulant
Source: PLoS ONE, Vol 14, Iss 11, p e0225286 (2019)
Publisher Information: Public Library of Science (PLoS), 2019.
Publication Year: 2019
Collection: LCC:Medicine
LCC:Science
Subject Terms: Medicine, Science
More Details: The simultaneous multi-slice EPI (SMS-EPI, a.k.a. MB-EPI) sequence has met immense popularity recently in functional neuroimaging. A still less common alternative is the use of 3D-EPI, which offers similar acceleration capabilities. The aim of this work was to compare the SMS-EPI and the 3D-EPI sequences in terms of sampling strategies for the detection of task-evoked activations at 7T using detection theory. To this end, the spatial and temporal resolutions of the sequences were matched (1.6 mm isotropic resolution, TR = 1200 ms) and their excitation profiles were homogenized by means of calibration-free parallel-transmission (Universal Pulses). We used a fast-event "localizer" paradigm of 5:20 min in order to probe sensorimotor functions (visual, auditory and motor tasks) as well as higher level functions (language comprehension, mental calculation), where results from a previous large-scale study at 3T (N = 81) served as ground-truth reference for the brain areas implicated in each cognitive function. In the current study, ten subjects were scanned while their activation maps were generated for each cognitive function with the GLM analysis. The SMS-EPI and 3D-EPI sequences were compared in terms of raw tSNR, t-score testing for the mean signal, activation strength and accuracy of the robust sensorimotor functions. To this end, the sensitivity and specificity of these contrasts were computed by comparing their activation maps to the reference brain areas obtained in the 3T study. Estimated flip angle distributions in the brain reported a normalized root mean square deviation from the target value below 10% for both sequences. The analysis of the t-score testing for the mean signal revealed temporal noise correlations, suggesting the use of this metric instead of the traditional tSNR for testing fMRI sequences. The SMS-EPI and 3D-EPI thereby yielded similar performance from a detection theory perspective.
Document Type: article
File Description: electronic resource
Language: English
ISSN: 1932-6203
Relation: https://doaj.org/toc/1932-6203
DOI: 10.1371/journal.pone.0225286
Access URL: https://doaj.org/article/97fc7d91637642e082d3443654d1e506
Accession Number: edsdoj.97fc7d91637642e082d3443654d1e506
Database: Directory of Open Access Journals
Full text is not displayed to guests.
More Details
ISSN:19326203
DOI:10.1371/journal.pone.0225286
Published in:PLoS ONE
Language:English