Highly Specific and Rapid Detection of Hepatitis C Virus Using RT-LAMP-Coupled CRISPR–Cas12 Assay

Bibliographic Details
Title: Highly Specific and Rapid Detection of Hepatitis C Virus Using RT-LAMP-Coupled CRISPR–Cas12 Assay
Authors: Nang Kham-Kjing, Nicole Ngo-Giang-Huong, Khajornsak Tragoolpua, Woottichai Khamduang, Sayamon Hongjaisee
Source: Diagnostics, Vol 12, Iss 7, p 1524 (2022)
Publisher Information: MDPI AG, 2022.
Publication Year: 2022
Collection: LCC:Medicine (General)
Subject Terms: hepatitis C virus, HCV RNA, chronic hepatitis C, point-of-care testing, RT-LAMP, CRISPR–Cas12, Medicine (General), R5-920
More Details: Hepatitis C virus (HCV) infection can be cured with pan-genotypic direct-acting antiviral agents. However, identifying individuals with current hepatitis C remains a major challenge, especially in resource-limited settings where access to or availability of molecular tests is still limited. The goal of this study was to develop and validate a molecular assay for the rapid detection of HCV RNA in resource-limited settings. It is based on a combination of reverse transcription loop-mediated isothermal amplification (RT-LAMP) with the clustered regularly interspaced short palindromic repeats–CRISPR-associated protein 12a (CRISPR–Cas12a) cleavage assay that allows the recognition of specific HCV nucleic acid sequences. Amplified products after the cleavage reactions can be visualized on lateral flow strips or measured with a fluorescence detector. When tested on clinical samples from individuals infected with HCV, HIV, or HBV, or from healthy donors, the RT-LAMP-coupled CRISPR–Cas12 assay yielded 96% sensitivity, 100% specificity, and 97% agreement as compared to the reference method (Roche COBAS AmpliPrep/COBAS TaqMan HCV Test). This assay could detect HCV RNA concentrations as low as 10 ng/µL (an estimated 2.38 Log10 IU/mL). Therefore, this sensitive and specific assay may represent an affordable and reliable point-of-care test for the identification of individuals with active hepatitis C in low-resource settings.
Document Type: article
File Description: electronic resource
Language: English
ISSN: 2075-4418
Relation: https://www.mdpi.com/2075-4418/12/7/1524; https://doaj.org/toc/2075-4418
DOI: 10.3390/diagnostics12071524
Access URL: https://doaj.org/article/8fa2e368d51e4da791fdcd68a189b85b
Accession Number: edsdoj.8fa2e368d51e4da791fdcd68a189b85b
Database: Directory of Open Access Journals
Full text is not displayed to guests.
More Details
ISSN:20754418
DOI:10.3390/diagnostics12071524
Published in:Diagnostics
Language:English