Volume assessment magnetic resonance imaging technique for monitoring perianal Crohn’s fistulas

Bibliographic Details
Title: Volume assessment magnetic resonance imaging technique for monitoring perianal Crohn’s fistulas
Authors: Phillip F. C. Lung, Kapil Sahnan, David Burling, James Burn, Phillip Tozer, Nuha Yassin, Samuel O. Adegbola, Rachel Baldwin-Cleland, Janindra Warusavitarne, Arun Gupta, Omar Faiz, Robin K. S. Phillips, Ailsa L. Hart
Source: Therapeutic Advances in Gastroenterology, Vol 11 (2018)
Publisher Information: SAGE Publishing, 2018.
Publication Year: 2018
Collection: LCC:Diseases of the digestive system. Gastroenterology
Subject Terms: Diseases of the digestive system. Gastroenterology, RC799-869
More Details: Background: Perianal Crohn’s fistula and their response to anti-tumour necrosis factor (TNF) therapies are best assessed with magnetic resonance imaging (MRI), but radiologist reporting is subjective and variable. This study investigates whether segmentation software could provide precise and reproducible objective measurements of fistula volume. Methods: Retrospective analysis of patients with perianal Crohn’s fistula at our institution between 2007 and 2013. Pre- and post-biologic MRI scans were used with varying time intervals. A total of two radiologists recorded fistula volumes, mean signal intensity and time taken to measure fistula volumes using validated Open Source segmentation software. A total of three radiologists assessed fistula response to treatment (improved, worse or unchanged) by comparing MRI scans. Results: A total of 18 cases were reviewed for this pilot study. Inter-observer variability was very good for volume and mean signal intensity; intra-class correlation (ICC) 0.95 [95% confidence interval (CI) 0.91–0.98] and 0.95 (95% CI 0.90–0.97) respectively. Intra-observer variability was very good for volume and mean signal intensity; ICC 0.99 (95% CI 0.97–0.99) and 0.98 (95% CI 0.95–0.99) respectively. Average time taken to measure fistula volume was 202 s and 250 s for readers 1 and 2. Agreement between three specialist radiologists was good [kappa 0.69 (95% CI 0.49–0.90)] for the subjective assessment of fistula response. Significant association was found between objective percentage volume change and subjective consensus agreement of response ( p = 0.001). Median volume change for improved, stable or worsening fistula response was −67% [interquartile range (IQR): −78, −47], 0% (IQR: −16, +17), and +487% (IQR: +217, +559) respectively. Conclusion: Quantification of fistula volumes and signal intensities is feasible and reliable, providing an objective measure of perianal Crohn’s fistula and response to treatment.
Document Type: article
File Description: electronic resource
Language: English
ISSN: 1756-2848
17562848
Relation: https://doaj.org/toc/1756-2848
DOI: 10.1177/1756284818793609
Access URL: https://doaj.org/article/e720ecf4924e4d6093ca9a1d8ddbe11c
Accession Number: edsdoj.720ecf4924e4d6093ca9a1d8ddbe11c
Database: Directory of Open Access Journals
More Details
ISSN:17562848
DOI:10.1177/1756284818793609
Published in:Therapeutic Advances in Gastroenterology
Language:English