Academic Journal
Soft wireless sternal patch to detect systemic vasoconstriction using photoplethysmography
Title: | Soft wireless sternal patch to detect systemic vasoconstriction using photoplethysmography |
---|---|
Authors: | Nathan Zavanelli, Sung Hoon Lee, Matthew Guess, Woon-Hong Yeo |
Source: | iScience, Vol 26, Iss 3, Pp 106184- (2023) |
Publisher Information: | Elsevier, 2023. |
Publication Year: | 2023 |
Collection: | LCC:Science |
Subject Terms: | Health sciences, Biological sciences, Biotechnology, Bioelectronics, Engineering, Science |
More Details: | Summary: Vasoconstriction is a crucial physiological process that serves as the body’s primary blood pressure regulation mechanism and a key marker of numerous harmful health conditions. The ability to detect vasoconstriction in real time would be crucial for detecting blood pressure, identifying sympathetic arousals, characterizing patient wellbeing, detecting sickle cell anemia attacks early, and identifying complications caused by hypertension medications. However, vasoconstriction manifests weakly in traditional photoplethysmogram (PPG) measurement locations, like the finger, toe, and ear. Here, we report a wireless, fully integrated, soft sternal patch to capture PPG signals from the sternum, an anatomical region that exhibits a robust vasoconstrictive response. With healthy controls, the device is highly capable of detecting vasoconstriction induced endogenously and exogenously. Furthermore, in overnight trials with patients with sleep apnea, the device shows a high agreement (r2 = 0.74) in vasoconstriction detection with a commercial system, demonstrating its potential use in portable, continuous, long-term vasoconstriction monitoring. |
Document Type: | article |
File Description: | electronic resource |
Language: | English |
ISSN: | 2589-0042 |
Relation: | http://www.sciencedirect.com/science/article/pii/S2589004223002614; https://doaj.org/toc/2589-0042 |
DOI: | 10.1016/j.isci.2023.106184 |
Access URL: | https://doaj.org/article/71981aadeb1e4bd785a17bc2dd40bd72 |
Accession Number: | edsdoj.71981aadeb1e4bd785a17bc2dd40bd72 |
Database: | Directory of Open Access Journals |
FullText | Links: – Type: other Url: https://resolver.ebsco.com:443/public/rma-ftfapi/ejs/direct?AccessToken=4D368BAA72D871EA39C1&Show=Object Text: Availability: 0 CustomLinks: – Url: https://www.doi.org/10.1016/j.isci.2023.106184? Name: ScienceDirect (all content)-s8985755 Category: fullText Text: View record from ScienceDirect MouseOverText: View record from ScienceDirect – Url: https://resolver.ebsco.com/c/xy5jbn/result?sid=EBSCO:edsdoj&genre=article&issn=25890042&ISBN=&volume=26&issue=3&date=20230301&spage=&pages=&title=iScience&atitle=Soft%20wireless%20sternal%20patch%20to%20detect%20systemic%20vasoconstriction%20using%20photoplethysmography&aulast=Nathan%20Zavanelli&id=DOI:10.1016/j.isci.2023.106184 Name: Full Text Finder (for New FTF UI) (s8985755) Category: fullText Text: Find It @ SCU Libraries MouseOverText: Find It @ SCU Libraries – Url: https://doaj.org/article/71981aadeb1e4bd785a17bc2dd40bd72 Name: EDS - DOAJ (s8985755) Category: fullText Text: View record from DOAJ MouseOverText: View record from DOAJ |
---|---|
Header | DbId: edsdoj DbLabel: Directory of Open Access Journals An: edsdoj.71981aadeb1e4bd785a17bc2dd40bd72 RelevancyScore: 961 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 961.003051757813 |
IllustrationInfo | |
Items | – Name: Title Label: Title Group: Ti Data: Soft wireless sternal patch to detect systemic vasoconstriction using photoplethysmography – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Nathan+Zavanelli%22">Nathan Zavanelli</searchLink><br /><searchLink fieldCode="AR" term="%22Sung+Hoon+Lee%22">Sung Hoon Lee</searchLink><br /><searchLink fieldCode="AR" term="%22Matthew+Guess%22">Matthew Guess</searchLink><br /><searchLink fieldCode="AR" term="%22Woon-Hong+Yeo%22">Woon-Hong Yeo</searchLink> – Name: TitleSource Label: Source Group: Src Data: iScience, Vol 26, Iss 3, Pp 106184- (2023) – Name: Publisher Label: Publisher Information Group: PubInfo Data: Elsevier, 2023. – Name: DatePubCY Label: Publication Year Group: Date Data: 2023 – Name: Subset Label: Collection Group: HoldingsInfo Data: LCC:Science – Name: Subject Label: Subject Terms Group: Su Data: <searchLink fieldCode="DE" term="%22Health+sciences%22">Health sciences</searchLink><br /><searchLink fieldCode="DE" term="%22Biological+sciences%22">Biological sciences</searchLink><br /><searchLink fieldCode="DE" term="%22Biotechnology%22">Biotechnology</searchLink><br /><searchLink fieldCode="DE" term="%22Bioelectronics%22">Bioelectronics</searchLink><br /><searchLink fieldCode="DE" term="%22Engineering%22">Engineering</searchLink><br /><searchLink fieldCode="DE" term="%22Science%22">Science</searchLink> – Name: Abstract Label: Description Group: Ab Data: Summary: Vasoconstriction is a crucial physiological process that serves as the body’s primary blood pressure regulation mechanism and a key marker of numerous harmful health conditions. The ability to detect vasoconstriction in real time would be crucial for detecting blood pressure, identifying sympathetic arousals, characterizing patient wellbeing, detecting sickle cell anemia attacks early, and identifying complications caused by hypertension medications. However, vasoconstriction manifests weakly in traditional photoplethysmogram (PPG) measurement locations, like the finger, toe, and ear. Here, we report a wireless, fully integrated, soft sternal patch to capture PPG signals from the sternum, an anatomical region that exhibits a robust vasoconstrictive response. With healthy controls, the device is highly capable of detecting vasoconstriction induced endogenously and exogenously. Furthermore, in overnight trials with patients with sleep apnea, the device shows a high agreement (r2 = 0.74) in vasoconstriction detection with a commercial system, demonstrating its potential use in portable, continuous, long-term vasoconstriction monitoring. – Name: TypeDocument Label: Document Type Group: TypDoc Data: article – Name: Format Label: File Description Group: SrcInfo Data: electronic resource – Name: Language Label: Language Group: Lang Data: English – Name: ISSN Label: ISSN Group: ISSN Data: 2589-0042 – Name: NoteTitleSource Label: Relation Group: SrcInfo Data: http://www.sciencedirect.com/science/article/pii/S2589004223002614; https://doaj.org/toc/2589-0042 – Name: DOI Label: DOI Group: ID Data: 10.1016/j.isci.2023.106184 – Name: URL Label: Access URL Group: URL Data: <link linkTarget="URL" linkTerm="https://doaj.org/article/71981aadeb1e4bd785a17bc2dd40bd72" linkWindow="_blank">https://doaj.org/article/71981aadeb1e4bd785a17bc2dd40bd72</link> – Name: AN Label: Accession Number Group: ID Data: edsdoj.71981aadeb1e4bd785a17bc2dd40bd72 |
PLink | https://login.libproxy.scu.edu/login?url=https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsdoj&AN=edsdoj.71981aadeb1e4bd785a17bc2dd40bd72 |
RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.isci.2023.106184 Languages: – Text: English Subjects: – SubjectFull: Health sciences Type: general – SubjectFull: Biological sciences Type: general – SubjectFull: Biotechnology Type: general – SubjectFull: Bioelectronics Type: general – SubjectFull: Engineering Type: general – SubjectFull: Science Type: general Titles: – TitleFull: Soft wireless sternal patch to detect systemic vasoconstriction using photoplethysmography Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Nathan Zavanelli – PersonEntity: Name: NameFull: Sung Hoon Lee – PersonEntity: Name: NameFull: Matthew Guess – PersonEntity: Name: NameFull: Woon-Hong Yeo IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 03 Type: published Y: 2023 Identifiers: – Type: issn-print Value: 25890042 Numbering: – Type: volume Value: 26 – Type: issue Value: 3 Titles: – TitleFull: iScience Type: main |
ResultId | 1 |