Noninvasive Ocular Surface Workup in Patients with Meibomian Gland Dysfunction Using Microwave-Heated Eye Bag

Bibliographic Details
Title: Noninvasive Ocular Surface Workup in Patients with Meibomian Gland Dysfunction Using Microwave-Heated Eye Bag
Authors: Rossi C, Vaccaro S, Borselli M, Carnovale Scalzo G, Toro MD, Scorcia V, Giannaccare G
Source: Clinical Ophthalmology, Vol Volume 18, Pp 853-858 (2024)
Publisher Information: Dove Medical Press, 2024.
Publication Year: 2024
Collection: LCC:Ophthalmology
Subject Terms: mgd, dry eye, ocular surface disease, warming device, eyelid, Ophthalmology, RE1-994
More Details: Costanza Rossi,1,* Sabrina Vaccaro,1,* Massimiliano Borselli,1 Giovanna Carnovale Scalzo,1 Mario Damiano Toro,2 Vincenzo Scorcia,1 Giuseppe Giannaccare3 1Department of Ophthalmology, University Magna Graecia of Catanzaro, Catanzaro, Italy; 2Eye Clinic, Public Health Department, University of Naples Federico II, Naples, Italy; 3Eye Clinic, Department of Surgical Sciences, University of Cagliari, Cagliari, Italy*These authors contributed equally to this workCorrespondence: Giuseppe Giannaccare, Ophthalmology, Chairman of Eye Clinic, Department of Surgical Sciences, University of Cagliari, Cagliari, Italy, Email giuseppe.giannaccare@unica.itPurpose: To report the outcomes of a novel microwave heating device (Blepha EyeBag®) used serially for the treatment of meibomian gland dysfunction (MGD).Patients and Methods: This prospective single center study was conducted at University Magna Graecia of Catanzaro. Patients were instructed to apply the compress twice daily for 15 days and once per day every two days, as reported in the package insert. Outcome measures were i) ocular surface disease index (OSDI) score, ii) tear meniscus height (TMH), iii) non-invasive keratograph break-up time (NIKBUT) (first and average), iv) meiboscore, v) bulbar redness. Evaluations were performed at baseline (T0) after 15 days (T1) and after 45 days of therapy (T2).Results: Overall, 19 patients with MGD (8 males, 11 females; mean age 64.58 ± 9.72 years) were included. The mean value of OSDI score showed a significant decrease from 28.16 ± 17.46 at T0 to 13.69 ± 7.62 at T2 (p=0.008). The mean value of NIKBUT first significantly increased from 6.67 ± 3.51 seconds (s) at T0 to 10.46 ± 4.64 at T2 (p=0.0121); in parallel, the mean value of NIKBUT average increased significantly from 11.09 ± 4.15 s at T0 to 14.95 ± 4.85 at T2 (p=0.0049). No significant differences were detected at each time point for bulbar redness, meiboscore and TMH. Throughout the entire study, no adverse events were recorded.Conclusion: The microwave-heated eye bag treatment is both safe and effective for treatment of MGD, being able to significantly ameliorate both patient-reported symptoms and tear film stability.Keywords: MGD, dry eye, ocular surface disease, warming device, eyelid
Document Type: article
File Description: electronic resource
Language: English
ISSN: 1177-5483
Relation: https://www.dovepress.com/noninvasive-ocular-surface-workup-in-patients-with-meibomian-gland-dys-peer-reviewed-fulltext-article-OPTH; https://doaj.org/toc/1177-5483
Access URL: https://doaj.org/article/d5ef6dd64a0e4b35b005a8497de61f0f
Accession Number: edsdoj.5ef6dd64a0e4b35b005a8497de61f0f
Database: Directory of Open Access Journals
More Details
ISSN:11775483
Published in:Clinical Ophthalmology
Language:English