Noncontrast free-breathing respiratory self-navigated coronary artery cardiovascular magnetic resonance angiography at 3 T using lipid insensitive binomial off-resonant excitation (LIBRE)

Bibliographic Details
Title: Noncontrast free-breathing respiratory self-navigated coronary artery cardiovascular magnetic resonance angiography at 3 T using lipid insensitive binomial off-resonant excitation (LIBRE)
Authors: Jessica A. M. Bastiaansen, Ruud B. van Heeswijk, Matthias Stuber, Davide Piccini
Source: Journal of Cardiovascular Magnetic Resonance, Vol 21, Iss 1, Pp 1-11 (2019)
Publisher Information: Elsevier, 2019.
Publication Year: 2019
Collection: LCC:Diseases of the circulatory (Cardiovascular) system
Subject Terms: Coronary artery angiography, 3 T MRI, Water excitation, Fat suppression, Noncontrast, Vessel sharpness, Diseases of the circulatory (Cardiovascular) system, RC666-701
More Details: Abstract Background Robust and homogeneous lipid suppression is mandatory for coronary artery cardiovascular magnetic resonance (CMR) imaging since the coronary arteries are commonly embedded in epicardial fat. However, effective large volume lipid suppression becomes more challenging when performing radial whole-heart coronary artery CMR for respiratory self-navigation and the problem may even be exacerbated at increasing magnetic field strengths. Incomplete fat suppression not only hinders a correct visualization of the coronary vessels and generates image artifacts, but may also affect advanced motion correction methods. The aim of this study was to evaluate a recently reported lipid insensitive CMR method when applied to a noncontrast self-navigated coronary artery CMR acquisitions at 3 T, and to compare it to more conventional fat suppression techniques. Methods Lipid insensitive binomial off resonant excitation (LIBRE) radiofrequency excitation pulses were included into a self-navigated 3D radial GRE coronary artery CMR sequence at 3 T. LIBRE was compared against a conventional CHESS fat saturation (FS) and a binomial 1–180°-1 water excitation (WE) pulse. First, fat suppression of all techniques was numerically characterized using Matlab and experimentally validated in phantoms and in legs of human volunteers. Subsequently, free-breathing self-navigated coronary artery CMR was performed using the LIBRE pulse as well as FS and WE in ten healthy subjects. Myocardial, arterial and chest fat signal-to-noise ratios (SNR), as well as coronary vessel conspicuity were quantitatively compared among those scans. Results The results obtained in the simulations were confirmed by the experimental validations as LIBRE enabled near complete fat suppression for 3D radial imaging in vitro and in vivo. For self-navigated whole-heart coronary artery CMR at 3 T, fat SNR was significantly attenuated using LIBRE compared with conventional FS. LIBRE increased the right coronary artery (RCA) vessel sharpness significantly (37 ± 9% (LIBRE) vs. 29 ± 8% (FS) and 30 ± 8% (WE), both p
Document Type: article
File Description: electronic resource
Language: English
ISSN: 1532-429X
Relation: http://link.springer.com/article/10.1186/s12968-019-0543-6; https://doaj.org/toc/1532-429X
DOI: 10.1186/s12968-019-0543-6
Access URL: https://doaj.org/article/5d83237e66e340f2b3e8196003a2bc5c
Accession Number: edsdoj.5d83237e66e340f2b3e8196003a2bc5c
Database: Directory of Open Access Journals
More Details
ISSN:1532429X
DOI:10.1186/s12968-019-0543-6
Published in:Journal of Cardiovascular Magnetic Resonance
Language:English