Academic Journal
Comparison of a non-invasive point-of-care measurement of anemia to conventionally used HemoCue devices in Gambella refugee camp, Ethiopia, 2022.
Title: | Comparison of a non-invasive point-of-care measurement of anemia to conventionally used HemoCue devices in Gambella refugee camp, Ethiopia, 2022. |
---|---|
Authors: | Frederica Smith, Meseret Woldeyohannes, Millicent Lusigi, Kaitlyn L I Samson, Blessing Tapera Mureverwi, Dorothy Gazarwa, Naser Mohmand, Terry Theuri, Eva Leidman |
Source: | PLoS ONE, Vol 20, Iss 1, p e0313319 (2025) |
Publisher Information: | Public Library of Science (PLoS), 2025. |
Publication Year: | 2025 |
Collection: | LCC:Medicine LCC:Science |
Subject Terms: | Medicine, Science |
More Details: | Annual surveys of refugees in Gambella, Ethiopia suggest that anemia is a persistent public health problem among non-pregnant women of reproductive age (NP-WRA, 15-49 years). Measurement of anemia in most refugee camp settings is conducted using an invasive HemoCue 301. We assessed the accuracy and precision of a non-invasive, pulse CO-oximeter in measuring anemia among NP-WRA in four Gambella refugee camps. We conducted a population-representative household survey between November 7 and December 4, 2022. Hemoglobin (Hb) concentration was measured by HemoCue 301, using capillary blood, and Rad-67, a novel non-invasive device. We collected four measurements per participant: two per device. We calculated Rad-67 bias and precision of Hb measurements and sensitivity and specificity of detecting anemia. Of the 812 NP-WRAs selected, 807 (99%) participated in the study. Anemia was detected in 39% of NP-WRA as classified by the Rad-67 compared with 47% of NP-WRA as classified by the HemoCue 301. Average bias of Rad-67 measurements was 1.1 ± 1.0 SD g/dL, using HemoCue 301 as a comparator. Absolute mean difference between the first and second measurements was 0.9 g/dL (95% CI 0.8, 0.9) using the Rad-67, compared with 0.6 g/dL (95% CI 0.5, 0.6) using the HemoCue 301. The Rad-67 had 49% sensitivity and 70% specificity for detecting anemia, compared with the HemoCue 301. The Rad-67 can be a useful tool for anemia screening; however, lower accuracy and precision, and poor sensitivity suggest it cannot immediately replace the HemoCue 301 in the study area. |
Document Type: | article |
File Description: | electronic resource |
Language: | English |
ISSN: | 1932-6203 |
Relation: | https://doaj.org/toc/1932-6203 |
DOI: | 10.1371/journal.pone.0313319 |
Access URL: | https://doaj.org/article/d43d9bcf47ac46db99dc5219baef6b05 |
Accession Number: | edsdoj.43d9bcf47ac46db99dc5219baef6b05 |
Database: | Directory of Open Access Journals |
Full text is not displayed to guests. | Login for full access. |
ISSN: | 19326203 |
---|---|
DOI: | 10.1371/journal.pone.0313319 |
Published in: | PLoS ONE |
Language: | English |