Comparison of a non-invasive point-of-care measurement of anemia to conventionally used HemoCue devices in Gambella refugee camp, Ethiopia, 2022.

Bibliographic Details
Title: Comparison of a non-invasive point-of-care measurement of anemia to conventionally used HemoCue devices in Gambella refugee camp, Ethiopia, 2022.
Authors: Frederica Smith, Meseret Woldeyohannes, Millicent Lusigi, Kaitlyn L I Samson, Blessing Tapera Mureverwi, Dorothy Gazarwa, Naser Mohmand, Terry Theuri, Eva Leidman
Source: PLoS ONE, Vol 20, Iss 1, p e0313319 (2025)
Publisher Information: Public Library of Science (PLoS), 2025.
Publication Year: 2025
Collection: LCC:Medicine
LCC:Science
Subject Terms: Medicine, Science
More Details: Annual surveys of refugees in Gambella, Ethiopia suggest that anemia is a persistent public health problem among non-pregnant women of reproductive age (NP-WRA, 15-49 years). Measurement of anemia in most refugee camp settings is conducted using an invasive HemoCue 301. We assessed the accuracy and precision of a non-invasive, pulse CO-oximeter in measuring anemia among NP-WRA in four Gambella refugee camps. We conducted a population-representative household survey between November 7 and December 4, 2022. Hemoglobin (Hb) concentration was measured by HemoCue 301, using capillary blood, and Rad-67, a novel non-invasive device. We collected four measurements per participant: two per device. We calculated Rad-67 bias and precision of Hb measurements and sensitivity and specificity of detecting anemia. Of the 812 NP-WRAs selected, 807 (99%) participated in the study. Anemia was detected in 39% of NP-WRA as classified by the Rad-67 compared with 47% of NP-WRA as classified by the HemoCue 301. Average bias of Rad-67 measurements was 1.1 ± 1.0 SD g/dL, using HemoCue 301 as a comparator. Absolute mean difference between the first and second measurements was 0.9 g/dL (95% CI 0.8, 0.9) using the Rad-67, compared with 0.6 g/dL (95% CI 0.5, 0.6) using the HemoCue 301. The Rad-67 had 49% sensitivity and 70% specificity for detecting anemia, compared with the HemoCue 301. The Rad-67 can be a useful tool for anemia screening; however, lower accuracy and precision, and poor sensitivity suggest it cannot immediately replace the HemoCue 301 in the study area.
Document Type: article
File Description: electronic resource
Language: English
ISSN: 1932-6203
Relation: https://doaj.org/toc/1932-6203
DOI: 10.1371/journal.pone.0313319
Access URL: https://doaj.org/article/d43d9bcf47ac46db99dc5219baef6b05
Accession Number: edsdoj.43d9bcf47ac46db99dc5219baef6b05
Database: Directory of Open Access Journals
Full text is not displayed to guests.
More Details
ISSN:19326203
DOI:10.1371/journal.pone.0313319
Published in:PLoS ONE
Language:English