Title: |
Evaluation of different mathematical models and different b-value ranges of diffusion-weighted imaging in peripheral zone prostate cancer detection using b-value up to 4500 s/mm2. |
Authors: |
Zhaoyan Feng, Xiangde Min, Daniel J A Margolis, Caohui Duan, Yuping Chen, Vivek Kumar Sah, Nabin Chaudhary, Basen Li, Zan Ke, Peipei Zhang, Liang Wang |
Source: |
PLoS ONE, Vol 12, Iss 2, p e0172127 (2017) |
Publisher Information: |
Public Library of Science (PLoS), 2017. |
Publication Year: |
2017 |
Collection: |
LCC:Medicine LCC:Science |
Subject Terms: |
Medicine, Science |
More Details: |
OBJECTIVES:To evaluate the diagnostic performance of different mathematical models and different b-value ranges of diffusion-weighted imaging (DWI) in peripheral zone prostate cancer (PZ PCa) detection. METHODS:Fifty-six patients with histologically proven PZ PCa who underwent DWI-magnetic resonance imaging (MRI) using 21 b-values (0-4500 s/mm2) were included. The mean signal intensities of the regions of interest (ROIs) placed in benign PZs and cancerous tissues on DWI images were fitted using mono-exponential, bi-exponential, stretched-exponential, and kurtosis models. The b-values were divided into four ranges: 0-1000, 0-2000, 0-3200, and 0-4500 s/mm2, grouped as A, B, C, and D, respectively. ADC, , D*, f, DDC, α, Dapp, and Kapp were estimated for each group. The adjusted coefficient of determination (R2) was calculated to measure goodness-of-fit. Receiver operating characteristic curve analysis was performed to evaluate the diagnostic performance of the parameters. RESULTS:All parameters except D* showed significant differences between cancerous tissues and benign PZs in each group. The area under the curve values (AUCs) of ADC were comparable in groups C and D (p = 0.980) and were significantly higher than those in groups A and B (p< 0.05 for all). The AUCs of ADC and Kapp in groups B and C were similar (p = 0.07 and p = 0.954), and were significantly higher than the other parameters (p< 0.001 for all). The AUCs of ADC in group D was slightly higher than Kapp (p = 0.002), and both were significantly higher than the other parameters (p< 0.001 for all). CONCLUSIONS:ADC derived from conventional mono-exponential high b-value (3200 s/mm2) models is an optimal parameter for PZ PCa detection. |
Document Type: |
article |
File Description: |
electronic resource |
Language: |
English |
ISSN: |
1932-6203 |
Relation: |
http://europepmc.org/articles/PMC5310778?pdf=render; https://doaj.org/toc/1932-6203 |
DOI: |
10.1371/journal.pone.0172127 |
Access URL: |
https://doaj.org/article/28937a02628447cd86904fe7afd088e4 |
Accession Number: |
edsdoj.28937a02628447cd86904fe7afd088e4 |
Database: |
Directory of Open Access Journals |