Measurement of absorbed dose rate in water phantom maintained at body temperature by 60Co irradiator – comparison of experimental results and Monte Carlo simulation

Bibliographic Details
Title: Measurement of absorbed dose rate in water phantom maintained at body temperature by 60Co irradiator – comparison of experimental results and Monte Carlo simulation
Authors: Kye Yong-Uk, Kim Hyo-Jin, Lee Ji-Eun, Seo Yun-Jae, Kim Jung-Ki, Jo Wol-Soon, Lee Dong-Yeon, Kang Yeong-Rok
Source: Nuclear Technology and Radiation Protection, Vol 36, Iss 3, Pp 289-293 (2021)
Publisher Information: VINCA Institute of Nuclear Sciences, 2021.
Publication Year: 2021
Collection: LCC:Nuclear and particle physics. Atomic energy. Radioactivity
Subject Terms: absorbed dose, water phantom, blood irradiation, standard calibration, mcnpx code, Nuclear and particle physics. Atomic energy. Radioactivity, QC770-798
More Details: To analyze the biological effects of radiation, it is important that the conditions of in vitro experiments match closely with those of in vivo experiments. In this study, we constructed an irradiation system to conduct irradiation experiments under conditions similar to those of in vivo experiments. The Dongnam Institute of Radiological and Medial Sciences has a gamma irradiator including 60Co radioisotope for research purposes and accreditation for standard calibration of the ion chamber. The temperature of the water phantom was maintained the same as that of the normal human body, and the physical dosimetry was carried out accurately using the ion chamber with traceability. We report the measurement of lateral profiles, depth profiles, and absorbed dose rate in water, Dw, at the irradiation location of the blood samples using a farmer-type ion chamber. We simulated the source, collimator, irradiator, phantom, and extra structure of the gamma irradiation system using the Monte Carlo code and compared the simulated and the experimental results. The experimentally and theoretically evaluated dose rates were 0.2975 ± 0.0055 Gymin–1 (at coverage factor k = 2) and 0.2978 ± 0.0052 Gymin–1 (at coverage factor k = 2) at source-to-surface distance of 100 cm and 5 gcm–2 depth in the water phantom, respectively. Blood irradiation will be conducted in vitro, under conditions similar to in vivo conditions, to provide the dose-response curve based on dosimetry with traceability.
Document Type: article
File Description: electronic resource
Language: English
ISSN: 1451-3994
1452-8185
Relation: https://doaj.org/toc/1451-3994; https://doaj.org/toc/1452-8185
DOI: 10.2298/NTRP2103289K
Access URL: https://doaj.org/article/0c8c126949804117ba1d0343881dcc22
Accession Number: edsdoj.0c8c126949804117ba1d0343881dcc22
Database: Directory of Open Access Journals
More Details
ISSN:14513994
14528185
DOI:10.2298/NTRP2103289K
Published in:Nuclear Technology and Radiation Protection
Language:English