2.8 Unique patterns of elastin degradation in ascending aortic aneurysms in bicuspid aortic valve patients

Bibliographic Details
Title: 2.8 Unique patterns of elastin degradation in ascending aortic aneurysms in bicuspid aortic valve patients
Authors: Ya Hua Chim, Hannah Davies, Omar Nawaytou, Mark Field, Jillian Madine, Riaz Akhtar
Source: Artery Research, Vol 25, Iss 1 (2020)
Publisher Information: BMC, 2020.
Publication Year: 2020
Collection: LCC:Specialties of internal medicine
LCC:Diseases of the circulatory (Cardiovascular) system
Subject Terms: Specialties of internal medicine, RC581-951, Diseases of the circulatory (Cardiovascular) system, RC666-701
More Details: Background: Bicuspid aortic valve patients (BAV) are associated with increased risk of ascending aortic aneurysms. However, is unclear whether matrix degradation varies in different ascending aneurysm aetiologies. Aim: To determine whether the micromechanical and biochemical properties elastin microstructure in BAV-A exhibit unique properties as compared to idiopathic degenerative aneurysm (DA) for the same aortic size. Methods: Aortic tissue was obtained from patients undergoing aneurysmal repair surgery (BAV-A; n = 15 and DA; n = 15). Coronary artery by-pass graft punch biopsies served as controls (CABG; n = 9). The elastic modulus (E) was measured with nanoindentation for the medial layer. Glycosaminoglycan (GAG), collagen and elastin levels were measured using biochemical assays. Verhoeff Van Gieson-stained sections were imaged for elastin microstructural quantification. Results: BAV-A had approximately 20% higher E relative to control and DA. There was no significance between DA and controls. Collagen level of BAV-A (36.9 ± 7.4 μg/mg) and DA (49.9 ± 10.9 μg/mg) was higher compared to the control (30.2 ± 13.1 μg/mg). GAG and elastin levels were not significant between the groups. Elastin segments were uniform in controls. Aneurysmal tissues had loss of segments close to the intima and adventitia layers. Although BAV-A and DA had more elastin segments compacted in the media, elastin segments were highly fragmented in DA. Conclusion: BAV-A has increased stiffness within the aortic wall relative to DA and control tissue. The spatial distribution of elastin demonstrated a unique profile of matrix degradation for BAV-A. The findings of this work are important for the development of future clinical treatment of BAV-A treatment.
Document Type: article
File Description: electronic resource
Language: English
ISSN: 1876-4401
Relation: https://www.atlantis-press.com/article/125934401/view; https://doaj.org/toc/1876-4401
DOI: 10.2991/artres.k.191224.013
Access URL: https://doaj.org/article/009070d3413e475fa73e8cc69c20a8a4
Accession Number: edsdoj.009070d3413e475fa73e8cc69c20a8a4
Database: Directory of Open Access Journals
More Details
ISSN:18764401
DOI:10.2991/artres.k.191224.013
Published in:Artery Research
Language:English