Mismatch study of C-ADS main linac

Bibliographic Details
Title: Mismatch study of C-ADS main linac
Authors: Meng, Cai, Tang, Jing-Yu, Pei, Shi-Lun, Fang, Yan
Publication Year: 2014
Collection: Physics (Other)
Subject Terms: Physics - Accelerator Physics
More Details: The ADS accelerator in China is a CW (Continuous-Wave) proton linac with 1.5 GeV in beam energy, 10 mA in beam current, and 15 MW in beam power. To meet the extremely low beam loss rate requirement and high reliability, it is very important to study the beam halo caused by beam mismatch, which is one major source of beam loss. To avoid the envelope instability, the phase advances per period are all smaller than 90 degree in the main linac design. In this paper, the results of the emittance growth and the envelope oscillations caused by mismatch in the main linac section are presented. To meet the emittance growth requirement, the transverse and longitudinal mismatch factors should be smaller than 0.4 and 0.3, respectively.
Comment: 6 pages, 9 figures
Document Type: Working Paper
DOI: 10.1088/1674-1137/39/9/097002
Access URL: http://arxiv.org/abs/1411.6133
Accession Number: edsarx.1411.6133
Database: arXiv
More Details
DOI:10.1088/1674-1137/39/9/097002