Radiomics and dosiomics approaches to estimate lung function after stereotactic body radiation therapy in patients with lung tumors.

Bibliographic Details
Title: Radiomics and dosiomics approaches to estimate lung function after stereotactic body radiation therapy in patients with lung tumors.
Authors: Ieko, Yoshiro, Kadoya, Noriyuki, Tanaka, Shohei, Kikuchi, Koyo, Yamamoto, Takaya, Ariga, Hisanori, Jingu, Keiichi
Source: Radiological Physics & Technology; Mar2025, Vol. 18 Issue 1, p238-248, 11p
Abstract: Lung function assessment is essential for determining the optimal treatment strategy for radiation therapy in patients with lung tumors. This study aimed to develop radiomics and dosiomics approaches to estimate pulmonary function test (PFT) results in post-stereotactic body radiation therapy (SBRT). Sixty-four patients with lung tumors who underwent SBRT were included. Models were created to estimate the PFT results at 0–6 months (Cohort 1) and 6–24 months (Cohort 2) after SBRT. Radiomics and dosiomics features were extracted from the computed tomography (CT) images and dose distributions, respectively. To estimate the PFT results, Models A (dose-volume histogram [DVH] + radiomics features) and B (DVH + radiomics + dosiomics features) were created. In the PFT results, the forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) were estimated using each model, and the ratio of FEV1 to FVC (FEV1/FVC) was calculated. The Pearson's correlation coefficient (Pearson r) and area under the curve (AUC) for FEV1/FVC (< 70%) were calculated. The models were evaluated by comparing them with the conventional calculation formulae (Conventional). The Pearson r (FEV1/FVC) values were 0.30, 0.64, and 0.69 for Conventional and Models A and B (Cohort 2), respectively, and the AUC (FEV1/FVC < 70%) values were 0.63, 0.80, and 0.78, respectively. This study demonstrates the possibility of estimating lung function after SBRT using radiomics and dosiomics features based on planning CT images and dose distributions. [ABSTRACT FROM AUTHOR]
Copyright of Radiological Physics & Technology is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Complementary Index
More Details
ISSN:18650333
DOI:10.1007/s12194-024-00877-9
Published in:Radiological Physics & Technology
Language:English