Bibliographic Details
Title: |
One-Year Visual and Refractive Outcomes of SmartPulse ® Technology in Transepithelial Photorefractive Keratectomy for Myopic and Astigmatic Patients. |
Authors: |
Margarit, Daiana-Andreea, Stanca, Horia Tudor, Mocanu, Valeria, Munteanu, Mihnea, Ferrari, Francis, Marius, Suta |
Source: |
Journal of Clinical Medicine; Oct2024, Vol. 13 Issue 20, p6182, 12p |
Subject Terms: |
EXCIMER lasers, ASTIGMATISM, VISUAL acuity, MYOPIA, OPHTHALMOLOGY, PHOTOREFRACTIVE keratectomy |
Abstract: |
Background/Objectives: This study aims to evaluate the efficacy, safety, and predictability of Transepithelial Photorefractive Keratectomy (TPRK) using the SmartPulse® technology excimer laser for the correction of myopia and myopic astigmatism, assessing visual and refractive outcomes over a one-year follow-up period. Methods: This retrospective cohort study analyzed data from patients who underwent TPRK at the Ophthalmology Department—"Victor Babes" University of Medicine and Pharmacy in Timisoara (Romania), between January 2019 and June 2023. The procedure was performed using the SmartPulse® Technology of the SmartSurfACE AMARIS 750S excimer laser (SCHWIND eye-tech-solutions, Kleinostheim, Germany). Preoperative assessments included visual acuity, refraction, and corneal measurements, with postoperative evaluations conducted for up to 12 months. Results: This study included 92 eyes from 46 patients (mean age 29.02 years, 63% male). At 12 months post-op, 100% achieved UDVA 20/25 or better, with an efficacy index of 1.01. Refractive accuracy was 96% within ±0.50 D of the target and astigmatism ≤ 0.50 D in 99% of eyes. The safety index was 1.01. Corneal haze occurred in 8.70% of eyes and was effectively managed with dexamethasone drops. Conclusions: TPRK with the SmartPulse® technology excimer laser demonstrated high efficacy and safety in correcting myopia and myopic astigmatism, achieving stable visual outcomes over one year. The procedure also showed excellent predictability with a low incidence of complications, supporting its use as a reliable refractive surgery option. [ABSTRACT FROM AUTHOR] |
|
Copyright of Journal of Clinical Medicine is the property of MDPI and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
Database: |
Complementary Index |