Pulmonary valve replacement in a large and tortuous right ventricle outflow tract with a 32 mm Myval valve under local anaesthesia: challenges and technical considerations: a case report.

Bibliographic Details
Title: Pulmonary valve replacement in a large and tortuous right ventricle outflow tract with a 32 mm Myval valve under local anaesthesia: challenges and technical considerations: a case report.
Authors: Houeijeh, Ali, Sudre, Arnaud, Juthier, Francis, Godart, François
Source: European Heart Journal Case Reports; Aug2023, Vol. 7 Issue 8, p1-5, 5p
Abstract: Background Pulmonary valve replacement in patients with congenital heart diseases and heart failure is challenging. Case summary Here, we describe a case of a patient who had surgical fallot repair with chronic heart failure. Investigations found severe biventricular dysfunction and enlargement due to chronic pulmonary regurgitation. The right ventricle outflow tract was tortuous and large with a diameter of 35 mm. Percutaneous pulmonary valve implantation (PPVI) was done after a challenging pre-stenting. A 32 mm Myval valve over-sized to 35 mm was used for PPVI, which yielded a good result. Discussion A 32 mm Myval valve is effective at extending the possibilities of PPVI in a large and tortuous right ventricle outflow tract not accessible for the other valves. [ABSTRACT FROM AUTHOR]
Copyright of European Heart Journal Case Reports is the property of Oxford University Press / USA and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Complementary Index
More Details
ISSN:25142119
DOI:10.1093/ehjcr/ytad322
Published in:European Heart Journal Case Reports
Language:English