Case series of catheter‐based arrhythmia ablation in 13 pregnant women. |
Authors: |
Mladoniczky, Sára, Nagy, Zsófia, Földesi, Csaba, Som, Zoltán, Bálint, Hajnalka O., Környei, László, Ruzsa, Diána, Fődi, Eszter, Simor, Tamás, Kardos, Attila |
Source: |
Clinical Cardiology; Aug2023, Vol. 46 Issue 8, p942-949, 8p |
Subject Terms: |
PREGNANT women, ARRHYTHMIA, BODY surface mapping, VENTRICULAR tachycardia, CRYOSURGERY, CATHETER ablation, THERAPEUTICS, TACHYCARDIA |
Abstract: |
Background: Catheter ablation is a rarely used procedure to treat arrhythmias during pregnancy. Hypothesis: In the case of maternal arrhythmia during pregnancy, zero‐fluoroscopic catheter ablation is preferable to medical treatment. Methods: Between April 2014 and September 2021, we examined the demographic data, procedural parameters, and fetal and maternal outcomes in pregnant women undergoing ablation at the Gottsegen National Cardiovascular Center and University of Pécs Medical School, Heart Institute. Results: Fourteen procedures (14 electrophysiological studies [EPS], 13 ablations) performed on 13 pregnant women (age 30.3 ± 5.2 years, primipara n = 6) were studied. During EPS, 12 patients had inducible arrhythmias. Atrial tachycardia was confirmed in three, atrioventricular re‐entry tachycardia via manifest accessory pathway (AP) in three, and via concealed AP in one case. Atrioventricular nodal re‐entry tachycardia was confirmed in three and sustained monomorphic ventricular tachycardia in two cases. Eleven radiofrequency ablation (84.6%) and two cryoablation (15.4%) were performed. The electroanatomical mapping system was used in all cases. Transseptal puncture was performed in two cases (15.4%) due to left lateral APs. The mean procedure time was 76.0±33.0 minutes. All procedures were performed without fluoroscopy. No complications occurred. During the follow‐up, arrhythmia‐free survival was achieved in all cases, but in two patients, we used antiarrhythmic drugs (AADs) to achieve it. APGAR score was within the normal range in all cases [median (interquartile range), 9.0/10.0 (9.0–10.0/9.3–10.0)]. Conclusions: Zero‐fluoroscopic catheter ablation was an effective and safe treatment option for our 13 pregnant patients. Catheter ablation may have less side effects on fetal development than the use of AADs during pregnancy. [ABSTRACT FROM AUTHOR] |
|
Copyright of Clinical Cardiology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
Database: |
Complementary Index |