Clinical Outcomes and Lens Constant Optimization of the Zeiss CT Lucia 602 Lens Using a Modified Yamane Technique. |
Authors: |
Randerson, Edward L, Bogaard, Joseph D, Koenig, Lisa R, Hwang, Eileen S, Warren, Clinton C, Koenig, Steven B |
Source: |
Clinical Ophthalmology; Nov2020, Vol. 14, p3903-3912, 10p |
Subject Terms: |
PARS plana, CRYSTALLINE lens, CORNEAL transplantation, PHOTOREFRACTIVE keratectomy, INTRAOCULAR lenses, REFRACTIVE errors, VISUAL acuity |
Abstract: |
Purpose: To report the clinical and refractive outcomes of a modified Yamane technique for scleral fixation of the CT Lucia 602 lens. Design: Retrospective case series. Patients: One hundred twenty-one eyes with dislocated posterior chamber lens implants, surgical aphakia, subluxed crystalline lenses, capsular tear, anterior chamber, or iris sutured posterior chamber lens intolerance were included. Methods: Secondary implantation of the Zeiss CT Lucia 602 lens was performed by a single surgeon using a modified Yamane technique employing a single needle, rather than the double-needle approach. One hundred twelve eyes underwent simultaneous 3 port pars plana vitrectomy and 9 eyes had previously undergone posterior vitrectomy surgery. Exclusion criteria were age < 18, simultaneous glaucoma or corneal procedures, staged corneal transplantation, and follow-up < 30 days. Main Outcome Measures: A paired t-test was used to compare pre- and post-operative corrected distance visual acuity (CDVA), the mean predictive error, and the mean absolute predictive error between the manufacturer's and optimized constants for Hoffer Q, Holladay I, and SRK/T. Complication rates were reported. Results: One hundred twenty-one consecutive eyes with a mean follow-up of 237 days were included. The pre-operative CDVA was 0.871 ± 0.785 logMAR (mean ± standard deviation, Snellen equivalent 20/149), which improved to 0.401 ± 0.608 (Snellen equivalent 20/50) post-operatively. In 109 eyes with reliable postoperative refractions, the mean predictive refractive error (D) ± std was +0.74 ± 1.37 for Hoffer Q, +0.66 ± 1.41 for Holladay 1, and +0.47 ± 1.49 for SRK/T (p< 0.05). Refractive outcome analysis yielded a mean optimized personalized anterior chamber depth (pACD) of 5.69, Surgeon Factor of 1.79, and A constant of 118.56. Vision-limiting complications occurred in 11 eyes (9.1%). Conclusion: Scleral fixation of the CT Lucia 602 lens using a single-needle modification of the Yamane technique resulted in very good visual acuity, predictable postoperative refractive errors, but some vision-limiting complications in this heterogeneous group of eyes with significant comorbidities. [ABSTRACT FROM AUTHOR] |
|
Copyright of Clinical Ophthalmology is the property of Dove Medical Press Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
Database: |
Complementary Index |