Bibliographic Details
Title: |
Feasibility of Telementoring during Robot-Assisted Minimally Invasive Esophagectomy. |
Authors: |
den Boer, Robin B.1 (AUTHOR), de Jongh, Cas1 (AUTHOR), van Boxel, Gijs I.2 (AUTHOR), Rouanet, Philippe3 (AUTHOR), Mourregot, Anne3 (AUTHOR), Ruurda, Jelle P.1 (AUTHOR), van Hillegersberg, Richard1 (AUTHOR) |
Source: |
Digestive Surgery. 2025, Vol. 42 Issue 1, p1-8. 8p. |
Subject Terms: |
*SURGICAL education, *SURGICAL robots, *AUDIO communication, *RAMIE, *ESOPHAGECTOMY |
Abstract: |
Introduction: Telementoring could increase the quality, reduce the time, and increase cost efficiency of the proctoring program for robot-assisted minimally invasive esophagectomy (RAMIE). However, feasibility is unclear as no studies assessed telementoring for RAMIE. Methods: The feasibility of telementoring was assessed during the thoracic part of RAMIE procedures in three high-volume centers. RAMIEs were performed by trained surgeons, proctored by two experts. The primary outcome was the impact of the technology on conveying and understanding instructions. Results: Between December 2021 and December 2022, nine RAMIE procedures were proctored using telementoring. Overall quality of the telementoring technique was scored good to excellent (median score: good). The vast majority of the 24 proctor instructions were conveyed and understood fluently (n = 21, 96%). Most proctor instructions were aimed at improving surgical exposure (n = 9, 38%). The major point of criticism was the use of the audio as the communication through the headset of the performing surgeon was not accessible by the complete team. Discussion: Telementoring is deemed feasible for proctoring trained RAMIE surgeons after onsite proctoring. Technical improvements with regard to audio technology are warranted for broad implementation, especially in earlier training settings. The role of telementoring in the training pathway of learning surgeons needs clinical validation. [ABSTRACT FROM AUTHOR] |
|
Copyright of Digestive Surgery is the property of Karger AG and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
Database: |
Academic Search Complete |