Bibliographic Details
Title: |
Advanced low-power filter architecture for biomedical signals with adaptive tuning. |
Authors: |
Srinivasagan, Ramasamy1 (AUTHOR) rsamy@kfu.edu.sa |
Source: |
PLoS ONE. 1/23/2025, Vol. 19 Issue 1, p1-26. 26p. |
Subject Terms: |
*POWER capacitors, *DIGITAL-to-analog converters, *ELECTROENCEPHALOGRAPHY, *VOLTAGE, *EURO, *ELECTROCARDIOGRAPHY, *BIOMEDICAL signal processing |
Abstract: |
This paper presents a low-power, second-order composite source-follower-based filter architecture optimized for biomedical signal processing, particularly ECG and EEG applications. Source-follower-based filters are recommended in the literature for high-frequency applications due to their lower power consumption when compared to filters with alternative topologies. However, they are not suitable for biomedical applications requiring low cutoff frequencies as they are designed to operate in the saturation region. The major contribution in this work are the filter is made to operate in the weak inversion zone to reduce the area needed for the capacitor and the amount of power dissipated. Process variation is one of the major issues in the weak inversion regime. To overcome this, a unique method of compensating against fluctuations in process, voltage, and temperature is put forth based on magnitude comparison is another contribution. Key findings from post-layout simulations and experimental measurements demonstrate that the filter achieves a tunable cutoff frequency range of 0.5 Hz to 150 Hz, with a total power dissipation of only 6nW at 150 Hz. The design occupies a compact silicon area of 0.065 mm2 and offers a dynamic range of 75 dB. The measured results indicate that for a 300 mVpp signal swing, the top bound on THD is -40 dB. The filter's robustness against process, voltage, and temperature variations is validated through on-chip tuning using a current steering DAC, ensuring stable performance across different operating conditions. These results make the proposed filter a promising candidate for low-power biomedical devices. The recommended filter is developed and implemented using UMC-0.18μm CMOS technology with a 1.0V supply, and the IC is tapped out using an MPW run of Euro practice IC services. [ABSTRACT FROM AUTHOR] |
|
Copyright of PLoS ONE is the property of Public Library of Science and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
Database: |
Academic Search Complete |
Full text is not displayed to guests. |
Login for full access.
|