Exploration of the Conditions for Occurrence of Photoplethysmographic Signal Inversion above the Dorsalis Pedis Artery.

Bibliographic Details
Title: Exploration of the Conditions for Occurrence of Photoplethysmographic Signal Inversion above the Dorsalis Pedis Artery.
Authors: Jerve, Fredrik Wilsbeck1 (AUTHOR) dag.hjelme@ntnu.no, Hjelme, Dag Roar1 (AUTHOR), Kalvøy, Håvard2 (AUTHOR) hkalvoy@ous-hf.no, Allen, John3 (AUTHOR) ad5325@coventry.ac.uk, Tronstad, Christian2 (AUTHOR) fwjerve@hotmail.com
Source: Sensors (14248220). Oct2024, Vol. 24 Issue 20, p6505. 21p.
Subject Terms: *PERIPHERAL vascular diseases, *HYPEREMIA, *POSITION sensors, *SENSOR placement, *SURFACE temperature, *SKIN temperature
Abstract: Inversion of the photoplethysmographic (PPG) signal is a rarely reported case. This signal anomaly can have implications for PPG-based cardiovascular assessments. The conditions for PPG signal inversion in the vicinity of the dorsalis pedis (DPA) artery of the foot were investigated. Wireless multi-wavelength PPG sensing with skin-probe contact pressure and local skin temperature were studied at different sensor positions, and the occurrence of inversion (OOI) was investigated. Twelve healthy adult volunteers were studied over four LED wavelengths at three levels of contact pressure for 11 probe positions. A novel algorithm quantified the proportion of inverted samples with respect to the abovementioned variables. Our algorithm classifying inverted vs. non-inverted pulses achieved 98.3% accuracy. Ten of the participants had at least one inverted signal identified. The impact of interindividual variation on inversion prevalence was large, but different LEDs, relative position to the DPA and sensor contact pressure also affected OOI. Skin surface and room temperatures showed no impact on OOI. Lateral measurements showed 39.6% more inversion at maximum compared to minimum contact pressure. Mechanical capillary bed variations and arterial reflections during venous engorgement are considered viable explanations for our observations. These findings motivate an expanded study of the occurrence of PPG signal inversion. [ABSTRACT FROM AUTHOR]
Copyright of Sensors (14248220) is the property of MDPI and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Academic Search Complete
Full text is not displayed to guests.
More Details
ISSN:14248220
DOI:10.3390/s24206505
Published in:Sensors (14248220)
Language:English