Effects of helical condenser coil designs on the heating process of the domestic refrigerator for hot water production: A numerical study.

Bibliographic Details
Title: Effects of helical condenser coil designs on the heating process of the domestic refrigerator for hot water production: A numerical study.
Authors: Missaoui, Sami1,2 (AUTHOR) Missaouisami1988@gmail.com, Driss, Zied3 (AUTHOR), Ben Slama, Romdhane2 (AUTHOR), Chaouachi, Bechir2 (AUTHOR)
Source: Numerical Heat Transfer: Part A -- Applications. 2024, Vol. 85 Issue 3, p328-350. 23p.
Subject Terms: *HOT water, *HEAT transfer coefficient, *TUBES, *WATER distribution, *HEAT transfer, *NATURAL heat convection
Abstract: Enhancement of heat transfer characteristics in helical condenser coils by modifying the coil shape has been reported by many researchers. While the influence of different types of condenser coil designs on the operating performance of refrigeration machines for hot water production unit is available in the literature, there exists no published numerical or experimental analysis of the impact of geometric parameter of immersed helical condenser coil on heat transfer characteristics and water velocity distribution during water heating process, which is the subject of our article. With using CFD methodology, a numerical study was carried out to present the water velocity distribution with varying coil parameters such as pipe diameter, tube pitch, and turns number. After validating the numerical model by the experimental ones, the effect of coil parameters on water velocity distribution was examined. The results confirm that by reducing the coil pitch and increasing the tube diameter, an increase of the water velocity and a higher natural convection is obtained. On the other hand, the results indicate that with reducing the turns number, the water velocity and the heat transfer coefficient is also increasing. Indeed, the average water velocity of condenser coil with N = 11 turns is higher than the other two condenser coil structures, which presents 21.34% and 63.56% higher than that of N = 13 turns and N = 15 turns, respectively. Thus, this investigation could provide some guidance to obtain the optimum condenser coil structure for water heating process. [ABSTRACT FROM AUTHOR]
Copyright of Numerical Heat Transfer: Part A -- Applications is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Academic Search Complete
Full text is not displayed to guests.
More Details
ISSN:10407782
DOI:10.1080/10407782.2023.2186550
Published in:Numerical Heat Transfer: Part A -- Applications
Language:English