Bibliographic Details
Title: |
Testing of a custom, portable drill press to minimize probe misalignment in sap flow sensors. |
Authors: |
Beslity, Justin1 (AUTHOR) jobeslit@syr.edu, Shaw, Stephen B1 (AUTHOR) |
Source: |
Tree Physiology. Aug2023, Vol. 43 Issue 8, p1467-1477. 11p. |
Subject Terms: |
*FLOW sensors, *PLANT transpiration, *HEAT pulses, *MEASUREMENT errors, *PLANT ecology, *PLANT physiology |
Abstract: |
The accurate estimation of plant transpiration is critical to the fields of hydrology, plant physiology and ecology. Among the various methods of measuring transpiration in the field, the sap flow methods based on head pulses offers a cost-effective and energy-efficient option to directly measure the plant-level movement of water through the hydraulically active tissue. While authors have identified several possible sources of error in these measurements, one of the most common sources is misalignment of the sap flow probes due to user error. Though the effects of probe misalignment are well documented, no device or technique has been universally adopted to ensure the proper installation of sap flow probes. In this paper we compare the magnitude of misalignment errors among a 5 mm thick drilling template (DT), a 10 mm thick DT, and a custom designed, field-portable drill press. The different techniques were evaluated in the laboratory using a 7.5 cm wood block and in the field, comparing differences in measured sap flow. Based on analysis of holes drilled in the wood block, we found that the portable drill press was most effective in assuring that drill holes remained parallel, even at 7.5 cm depth. In field installations, nearly 50% of holes drilled with a 5 mm template needed to be redrilled while none needed to be when drilled with the drill press. Widespread use of a portable drill press when implementing the heat pulse method would minimize alignment uncertainty and allow a clearer understanding of other sources of uncertainty due to variability in tree species, age, or external drivers or transpiration. [ABSTRACT FROM AUTHOR] |
|
Copyright of Tree Physiology is the property of Oxford University Press / USA and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
Database: |
Academic Search Complete |
Full text is not displayed to guests. |
Login for full access.
|