Title: |
Detection and size measurements of kidney stones on virtual non-contrast reconstructions derived from dual-layer computed tomography in an ex vivo phantom setup. |
Authors: |
Reimer, R. P.1 robert.reimer@uk-koeln.de, Zaytoun, H.1, Klein, K.1, Sonnabend, K.1,2, Lennartz, S.1, Zopfs, D.1, Heidenreich, A.3, Maintz, D.1, Große Hokamp, N.1 |
Source: |
European Radiology. Apr2023, Vol. 33 Issue 4, p2995-3003. 9p. 1 Color Photograph, 1 Black and White Photograph, 4 Charts, 1 Graph. |
Subject Terms: |
*KIDNEY stones diagnosis, *COMPUTED tomography, *THERAPEUTIC use of iodine, *WILCOXON signed-rank test, *RADIOTHERAPY |
Abstract: |
Objectives: To systematically investigate the usability of virtual non-contrast reconstructions (VNC) derived from dual-layer CT (DLCT) for detection and size measurements of kidney stones with regards to different degrees of surrounding iodine-induced attenuation and radiation dose. Methods: Ninety-two kidney stones of varying size (3–14 mm) and composition were placed in a phantom filled with different contrast media/water mixtures exhibiting specific iodine-induced attenuation (0–1500 HU). DLCT-scans were acquired using CTDIvol of 2 mGy and 10 mGy. Conventional images (CI) and VNC0H-1500HU were reconstructed. Reference stone size was determined using a digital caliper (Man-M). Visibility and stone size were assessed. Statistical analysis was performed using the McNemar test, Wilcoxon test, and the coefficient of determination. Results: All stones were visible on CI0HU and VNC200HU. Starting at VNC400 HU, the detection rate decreased with increasing HU and was significantly lower as compared to CI0HU on VNC≥ 600HU (100.0 vs. 94.0%, p < 0.05). The overall detection rate was higher using 10 mGy as compared to 2 mGy protocol (87.9 vs. 81.8%; p < 0.001). Stone size was significantly overestimated on all VNC compared to Man-M (7.0 ± 3.5 vs. 6.6 ± 2.8 mm, p < 0.001). Again, the 10 mGy protocol tended to show a better correlation with Man-M as compared to 2 mGy protocol (R2 = 0.39–0.68 vs. R2 = 0.31–0.57). Conclusions: Detection and size measurements of kidney stones surrounded by contrast media on VNC are feasible. The detection rate of kidney stones decreases with increasing iodine-induced attenuation and with decreasing radiation dose as well as stone size, while remaining comparable to CI0HU on VNC ≤ 400 HU. Key Points: • The detection rate of kidney stones on VNC depends on the surrounding iodine-induced attenuation, the used radiation dose, and the stone size. • The detection rate of kidney stones on VNC decreases with greater iodine-induced attenuation and with lower radiation dose, particularly in small stones. • The visibility of kidney stones on VNC≤ 400 HUremains comparable to true-non-contrast scans even when using a low-dose technique. [ABSTRACT FROM AUTHOR] |
|
Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
Database: |
Academic Search Complete |