Evaluation of Different Cannulation Strategies for Aortic Arch Surgery Using a Cardiovascular Numerical Simulator.

Bibliographic Details
Title: Evaluation of Different Cannulation Strategies for Aortic Arch Surgery Using a Cardiovascular Numerical Simulator.
Authors: De Lazzari, Beatrice1 (AUTHOR) beatrice.delazzari@gmail.com, Capoccia, Massimo2,3 (AUTHOR), Cheshire, Nicholas J.4 (AUTHOR), Rosendahl, Ulrich P.4 (AUTHOR), Badagliacca, Roberto5 (AUTHOR), De Lazzari, Claudio6,7 (AUTHOR)
Source: Bioengineering (Basel). Jan2023, Vol. 10 Issue 1, p60. 22p.
Subject Terms: *INDUCED cardiac arrest, *BLOOD circulation, *THORACIC aorta, *CAROTID artery, *FEMORAL artery, *AORTA, *CARDIOVASCULAR surgery, *BLOOD flow
Abstract: Aortic disease has a significant impact on quality of life. The involvement of the aortic arch requires the preservation of blood supply to the brain during surgery. Deep hypothermic circulatory arrest is an established technique for this purpose, although neurological injury remains high. Additional techniques have been used to reduce risk, although controversy still remains. A three-way cannulation approach, including both carotid arteries and the femoral artery or the ascending aorta, has been used successfully for aortic arch replacement and redo procedures. We developed circuits of the circulation to simulate blood flow during this type of cannulation set up. The CARDIOSIMĀ© cardiovascular simulation platform was used to analyse the effect on haemodynamic and energetic parameters and the benefit derived in terms of organ perfusion pressure and flow. Our simulation approach based on lumped-parameter modelling, pressureā€“volume analysis and modified time-varying elastance provides a theoretical background to a three-way cannulation strategy for aortic arch surgery with correlation to the observed clinical practice. [ABSTRACT FROM AUTHOR]
Copyright of Bioengineering (Basel) is the property of MDPI and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Academic Search Complete
More Details
ISSN:23065354
DOI:10.3390/bioengineering10010060
Published in:Bioengineering (Basel)
Language:English