Title: |
Automatic Cardiac Structure Contouring for Small Datasets with Cascaded Deep Learning Models. |
Authors: |
van den Oever, L. B.1,2 l.b.van.den.oever@umcg.nl, Spoor, D. S.1, Crijns, A. P. G.1, Vliegenthart, R.3, Oudkerk, M.4, Veldhuis, R. N. J.5, de Bock, G. H.6, van Ooijen, P. M. A.1 |
Source: |
Journal of Medical Systems. May2022, Vol. 46 Issue 5, p1-7. 7p. 3 Color Photographs, 3 Charts, 1 Graph. |
Subject Terms: |
*COMPUTERS in medicine, *DEEP learning, *CRONBACH'S alpha, *RADIATION doses, *RADIOTHERAPY, *COMPUTED tomography, *ARTIFICIAL neural networks, *ALGORITHMS |
Abstract: |
Cardiac structure contouring is a time consuming and tedious manual activity used for radiotherapeutic dose toxicity planning. We developed an automatic cardiac structure segmentation pipeline for use in low-dose non-contrast planning CT based on deep learning algorithms for small datasets. Fifty CT scans were retrospectively selected and the whole heart, ventricles and atria were contoured. A two stage deep learning pipeline was trained on 41 non contrast planning CTs, tuned with 3 CT scans and validated on 6 CT scans. In the first stage, An InceptionResNetV2 network was used to identify the slices that contained cardiac structures. The second stage consisted of three deep learning models trained on the images containing cardiac structures to segment the structures. The three deep learning models predicted the segmentations/contours on axial, coronal and sagittal images and are combined to create the final prediction. The final accuracy of the pipeline was quantified on 6 volumes by calculating the Dice similarity coefficient (DC), 95% Hausdorff distance (95% HD) and volume ratios between predicted and ground truth volumes. Median DC and 95% HD of 0.96, 0.88, 0.92, 0.80 and 0.82, and 1.86, 2.98, 2.02, 6.16 and 6.46 were achieved for the whole heart, right and left ventricle, and right and left atria respectively. The median differences in volume were -4, -1, + 5, -16 and -20% for the whole heart, right and left ventricle, and right and left atria respectively. The automatic contouring pipeline achieves good results for whole heart and ventricles. Robust automatic contouring with deep learning methods seems viable for local centers with small datasets. [ABSTRACT FROM AUTHOR] |
|
Copyright of Journal of Medical Systems is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
Database: |
Academic Search Complete |