Defocused Spatially Offset Raman Spectroscopy in Media of Different Optical Properties for Biomedical Applications Using a Commercial Spatially Offset Raman Spectroscopy Device.

Bibliographic Details
Title: Defocused Spatially Offset Raman Spectroscopy in Media of Different Optical Properties for Biomedical Applications Using a Commercial Spatially Offset Raman Spectroscopy Device.
Authors: Vardaki, Martha Z.1 (AUTHOR) martha.vardaki@msl.ubc.ca, Devine, Dana V.2,3 (AUTHOR), Serrano, Katherine2,3 (AUTHOR), Simantiris, Nikolaos4 (AUTHOR), Blades, Michael W.5 (AUTHOR), Piret, James M.1,6 (AUTHOR), Turner, Robin F. B.1,5,7 (AUTHOR)
Source: Applied Spectroscopy. Feb2020, Vol. 74 Issue 2, p223-232. 10p.
Subject Terms: *RAMAN spectroscopy, *OPTICAL properties, *ERYTHROCYTES, *MASS media, *CELL suspensions
Abstract: In this study, we show how defocused spatially offset Raman spectroscopy (SORS) can be employed to recover chemical information from media of biomedical significance within sealed plastic transfusion and culture bags using a commercial SORS instrument. We demonstrate a simple approach to recover subsurface spectral information through a transparent barrier by optimizing the spatial offset of the defocused beam. The efficiency of the measurements is assessed in terms of the SORS ratio and signal-to-noise ratio (S/N) through a simple manual approach and an ordinary least squares model. By comparing the results for three different biological samples (red blood cell concentrate, pooled red cell supernatant and a suspension of Jurkat cells), we show that there is an optimum value of the offset parameter which yields the maximum S/N depending on the barrier material and optical properties of the ensemble contents. The approach was developed in the context of biomedical applications but is generally applicable to any three-layer system consisting of turbid content between transparent thin plastic barriers (i.e., front and back bag surfaces), particularly where the analyte of interest is dilute or not a strong scatterer. [ABSTRACT FROM AUTHOR]
Copyright of Applied Spectroscopy is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Academic Search Complete
More Details
ISSN:00037028
DOI:10.1177/0003702819884625
Published in:Applied Spectroscopy
Language:English