Converse mode piezoelectric coefficient for lead zirconate titanate thin film with interdigitated electrode.

Bibliographic Details
Title: Converse mode piezoelectric coefficient for lead zirconate titanate thin film with interdigitated electrode.
Authors: N Chidambaram1 c.nachiappan@gmail.com, D Balma1, R Nigon1, A Mazzalai1, R Matloub1, C S Sandu1, P Muralt1
Source: Journal of Micromechanics & Microengineering. Apr2015, Vol. 25 Issue 4, p1-1. 1p.
Subject Terms: *PIEZOELECTRIC materials, *LEAD zirconate titanate, *THIN films, *ELECTRODES, *CAPACITANCE meters
Abstract: The use of interdigitated electrodes (IDEs) in conjunction with ferroelectric thin films shows many attractive features for piezoelectric MEMS applications. In this work, growth of {1 0 0}-textured lead zirconate titanate (PZT) thin films was achieved on insulating MgO buffered, oxidized silicon substrates. IDEs were fabricated by lift-off techniques and cantilevers were formed by dicing. The deflection upon application of a sweeping voltage was measured as large signal response in parallel to the ferroelectric polarization (PV loop). Likewise, the small signal piezoelectric response was measured in parallel to the capacitance-voltage (CV) measurement. In this way, a complete picture of the ferroelectric–piezoelectric element was obtained. From the deflection, the in-plane piezoelectric stress in the PZT thin film was derived and, from this, the effective piezoelectric coefficients. For the latter, two types were defined: an engineering type corresponding to the average value along the IDE, which can directly be compared to coefficient of a parallel plate electrode (PPE) capacitor and a second one that approximately yields the idealized coefficient governing between the electrode fingers. The IDE structures were experimentally compared with PPE structures of identical film thickness. The resulting coefficients were of opposite sign, as expected. In spite of a much better polarization loop, the IDE device showed a lower average piezoelectric stress. The estimated peak value between the fingers was about the same as in the PPE device, corresponding to about 20 C m−2. Nevertheless, the result is very promising for cases where compressive piezoelectric stresses are required and for preventing cracking due to large piezoelectric tensile stresses in PPE systems. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Micromechanics & Microengineering is the property of IOP Publishing and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Academic Search Complete
More Details
ISSN:13616439
DOI:10.1088/0960-1317/25/4/045016
Published in:Journal of Micromechanics & Microengineering
Language:English