Comparison of OA-2000 and IOL Master 500 using in cataract patients with high myopia

Bibliographic Details
Title: Comparison of OA-2000 and IOL Master 500 using in cataract patients with high myopia
Authors: Ya-Li Du, Geng Wang, Hui-Chun Huang, Li-Yu Lin, Chuang Jin, Li-Fang Liu, Xiu-Ru Liu, Ming-Zhi Zhang
Source: International Journal of Ophthalmology, Vol 12, Iss 5, Pp 844-847 (2019)
Publisher Information: Press of International Journal of Ophthalmology (IJO PRESS), 2019.
Publication Year: 2019
Collection: LCC:Ophthalmology
Subject Terms: oa-2000, iol master 500, biometry measurement, iol power calculation, high myopia, cataract, Ophthalmology, RE1-994
More Details: This study was designed to compare optical biometry measurements and predicted refraction in cataract patients with high myopia [axial length (AL) ≥26 mm] using OA-2000 and IOL Master 500. Ocular biometry measurements were performed using both biometers before surgery. Uneventful cataract surgery was performed in all patients. Postoperative manifest refraction was obtained 3wk after surgery or later. A total of 67 eyes were examined. The AL, keratometry (K), and anterior chamber depth (ACD) of the two biometers showed excellent agreement. Predicted errors were similar and a strong positive correlation was observed (r=0.909). Out of 21 eyes (31.34%) with unsuccessful AL readings using the IOL Master 500, 20 eyes of them could be measured using OA-2000. Therefore, the biometric parameters measured by the two biometers showed good agreement. However, OA-2000 had a lower AL measurement failure rate.
Document Type: article
File Description: electronic resource
Language: English
ISSN: 2222-3959
2227-4898
Relation: http://www.ijo.cn/en_publish/2019/5/20190523.pdf; https://doaj.org/toc/2222-3959; https://doaj.org/toc/2227-4898
DOI: 10.18240/ijo.2019.05.23
Access URL: https://doaj.org/article/fd62847ee7a545e4820b3c5ecdc2d83a
Accession Number: edsdoj.fd62847ee7a545e4820b3c5ecdc2d83a
Database: Directory of Open Access Journals
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://resolver.ebsco.com/c/xy5jbn/result?sid=EBSCO:edsdoj&genre=article&issn=22223959&ISBN=&volume=12&issue=5&date=20190501&spage=844&pages=844-847&title=International Journal of Ophthalmology&atitle=Comparison%20of%20OA-2000%20and%20IOL%20Master%20500%20using%20in%20cataract%20patients%20with%20high%20myopia&aulast=Ya-Li%20Du&id=DOI:10.18240/ijo.2019.05.23
    Name: Full Text Finder (for New FTF UI) (s8985755)
    Category: fullText
    Text: Find It @ SCU Libraries
    MouseOverText: Find It @ SCU Libraries
  – Url: https://doaj.org/article/fd62847ee7a545e4820b3c5ecdc2d83a
    Name: EDS - DOAJ (s8985755)
    Category: fullText
    Text: View record from DOAJ
    MouseOverText: View record from DOAJ
Header DbId: edsdoj
DbLabel: Directory of Open Access Journals
An: edsdoj.fd62847ee7a545e4820b3c5ecdc2d83a
RelevancyScore: 929
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 928.741149902344
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Comparison of OA-2000 and IOL Master 500 using in cataract patients with high myopia
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Ya-Li+Du%22">Ya-Li Du</searchLink><br /><searchLink fieldCode="AR" term="%22Geng+Wang%22">Geng Wang</searchLink><br /><searchLink fieldCode="AR" term="%22Hui-Chun+Huang%22">Hui-Chun Huang</searchLink><br /><searchLink fieldCode="AR" term="%22Li-Yu+Lin%22">Li-Yu Lin</searchLink><br /><searchLink fieldCode="AR" term="%22Chuang+Jin%22">Chuang Jin</searchLink><br /><searchLink fieldCode="AR" term="%22Li-Fang+Liu%22">Li-Fang Liu</searchLink><br /><searchLink fieldCode="AR" term="%22Xiu-Ru+Liu%22">Xiu-Ru Liu</searchLink><br /><searchLink fieldCode="AR" term="%22Ming-Zhi+Zhang%22">Ming-Zhi Zhang</searchLink>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: International Journal of Ophthalmology, Vol 12, Iss 5, Pp 844-847 (2019)
– Name: Publisher
  Label: Publisher Information
  Group: PubInfo
  Data: Press of International Journal of Ophthalmology (IJO PRESS), 2019.
– Name: DatePubCY
  Label: Publication Year
  Group: Date
  Data: 2019
– Name: Subset
  Label: Collection
  Group: HoldingsInfo
  Data: LCC:Ophthalmology
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22oa-2000%22">oa-2000</searchLink><br /><searchLink fieldCode="DE" term="%22iol+master+500%22">iol master 500</searchLink><br /><searchLink fieldCode="DE" term="%22biometry+measurement%22">biometry measurement</searchLink><br /><searchLink fieldCode="DE" term="%22iol+power+calculation%22">iol power calculation</searchLink><br /><searchLink fieldCode="DE" term="%22high+myopia%22">high myopia</searchLink><br /><searchLink fieldCode="DE" term="%22cataract%22">cataract</searchLink><br /><searchLink fieldCode="DE" term="%22Ophthalmology%22">Ophthalmology</searchLink><br /><searchLink fieldCode="DE" term="%22RE1-994%22">RE1-994</searchLink>
– Name: Abstract
  Label: Description
  Group: Ab
  Data: This study was designed to compare optical biometry measurements and predicted refraction in cataract patients with high myopia [axial length (AL) ≥26 mm] using OA-2000 and IOL Master 500. Ocular biometry measurements were performed using both biometers before surgery. Uneventful cataract surgery was performed in all patients. Postoperative manifest refraction was obtained 3wk after surgery or later. A total of 67 eyes were examined. The AL, keratometry (K), and anterior chamber depth (ACD) of the two biometers showed excellent agreement. Predicted errors were similar and a strong positive correlation was observed (r=0.909). Out of 21 eyes (31.34%) with unsuccessful AL readings using the IOL Master 500, 20 eyes of them could be measured using OA-2000. Therefore, the biometric parameters measured by the two biometers showed good agreement. However, OA-2000 had a lower AL measurement failure rate.
– Name: TypeDocument
  Label: Document Type
  Group: TypDoc
  Data: article
– Name: Format
  Label: File Description
  Group: SrcInfo
  Data: electronic resource
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: ISSN
  Label: ISSN
  Group: ISSN
  Data: 2222-3959<br />2227-4898
– Name: NoteTitleSource
  Label: Relation
  Group: SrcInfo
  Data: http://www.ijo.cn/en_publish/2019/5/20190523.pdf; https://doaj.org/toc/2222-3959; https://doaj.org/toc/2227-4898
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.18240/ijo.2019.05.23
– Name: URL
  Label: Access URL
  Group: URL
  Data: <link linkTarget="URL" linkTerm="https://doaj.org/article/fd62847ee7a545e4820b3c5ecdc2d83a" linkWindow="_blank">https://doaj.org/article/fd62847ee7a545e4820b3c5ecdc2d83a</link>
– Name: AN
  Label: Accession Number
  Group: ID
  Data: edsdoj.fd62847ee7a545e4820b3c5ecdc2d83a
PLink https://login.libproxy.scu.edu/login?url=https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsdoj&AN=edsdoj.fd62847ee7a545e4820b3c5ecdc2d83a
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.18240/ijo.2019.05.23
    Languages:
      – Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 4
        StartPage: 844
    Subjects:
      – SubjectFull: oa-2000
        Type: general
      – SubjectFull: iol master 500
        Type: general
      – SubjectFull: biometry measurement
        Type: general
      – SubjectFull: iol power calculation
        Type: general
      – SubjectFull: high myopia
        Type: general
      – SubjectFull: cataract
        Type: general
      – SubjectFull: Ophthalmology
        Type: general
      – SubjectFull: RE1-994
        Type: general
    Titles:
      – TitleFull: Comparison of OA-2000 and IOL Master 500 using in cataract patients with high myopia
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Ya-Li Du
      – PersonEntity:
          Name:
            NameFull: Geng Wang
      – PersonEntity:
          Name:
            NameFull: Hui-Chun Huang
      – PersonEntity:
          Name:
            NameFull: Li-Yu Lin
      – PersonEntity:
          Name:
            NameFull: Chuang Jin
      – PersonEntity:
          Name:
            NameFull: Li-Fang Liu
      – PersonEntity:
          Name:
            NameFull: Xiu-Ru Liu
      – PersonEntity:
          Name:
            NameFull: Ming-Zhi Zhang
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 05
              Type: published
              Y: 2019
          Identifiers:
            – Type: issn-print
              Value: 22223959
            – Type: issn-print
              Value: 22274898
          Numbering:
            – Type: volume
              Value: 12
            – Type: issue
              Value: 5
          Titles:
            – TitleFull: International Journal of Ophthalmology
              Type: main
ResultId 1