Internal fit and marginal adaptation of all-ceramic implant-supported hybrid abutment crowns with custom-milled screw-channels on Titanium-base: in-vitro study

Bibliographic Details
Title: Internal fit and marginal adaptation of all-ceramic implant-supported hybrid abutment crowns with custom-milled screw-channels on Titanium-base: in-vitro study
Authors: Marwa Wagih Zaky Fouad Fakhr, Hesham Alansary, Eman Ezzat Youssef Hassanien
Source: BMC Oral Health, Vol 24, Iss 1, Pp 1-10 (2024)
Publisher Information: BMC, 2024.
Publication Year: 2024
Collection: LCC:Dentistry
Subject Terms: CAD/CAM, Lithium disilicate, Replica, Stereomicroscope, Ultra translucent zirconia, Dentistry, RK1-715
More Details: Abstract Background Advancements in digital dentistry helped in custom-milling screw-channels in implant-supported restorations; however, the fit of these restorations is still unclear especially for contemporary computer aided designing/computer aided manufacturing (CAD/CAM) materials. This study aimed to compare the internal and marginal fit of Ultra translucent multilayered zirconia versus lithium disilicate implant-supported hybrid abutment crowns (HACs) constructed with custom-milled screw-channels on Titanium-base. Materials and methods A total of 24 HACs with custom-milled screw-channels were constructed from lithium disilicate (Group LDS) and Ultra translucent multilayered zirconia (Group UT) using digital workflow (n = 12). The internal and marginal gaps of HACs on their corresponding Titanium-bases were assessed using replica technique and stereomicroscope, respectively. After testing for normality, quantitative data were expressed as mean and standard deviation and compared using independent t-test at a level of significance (P ≤ 0.05). Results There was no statistically significant difference between Group LDS and Group UT in terms of marginal and internal fit. The internal and marginal gaps in both groups were within the accepted values reported in literature. Conclusions UT and LDS HACs with custom-milled screw-channels demonstrated comparable and acceptable internal fit and marginal adaptations to Ti-base, which lied within the range reported in literature.
Document Type: article
File Description: electronic resource
Language: English
ISSN: 1472-6831
Relation: https://doaj.org/toc/1472-6831
DOI: 10.1186/s12903-024-04810-9
Access URL: https://doaj.org/article/366ef65e5f844a3aaf092de3955f65f9
Accession Number: edsdoj.366ef65e5f844a3aaf092de3955f65f9
Database: Directory of Open Access Journals
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://resolver.ebsco.com/c/xy5jbn/result?sid=EBSCO:edsdoj&genre=article&issn=14726831&ISBN=&volume=24&issue=1&date=20240901&spage=1&pages=1-10&title=BMC Oral Health&atitle=Internal%20fit%20and%20marginal%20adaptation%20of%20all-ceramic%20implant-supported%20hybrid%20abutment%20crowns%20with%20custom-milled%20screw-channels%20on%20Titanium-base%3A%20in-vitro%20study&aulast=Marwa%20Wagih%20Zaky%20Fouad%20Fakhr&id=DOI:10.1186/s12903-024-04810-9
    Name: Full Text Finder (for New FTF UI) (s8985755)
    Category: fullText
    Text: Find It @ SCU Libraries
    MouseOverText: Find It @ SCU Libraries
  – Url: https://doaj.org/article/366ef65e5f844a3aaf092de3955f65f9
    Name: EDS - DOAJ (s8985755)
    Category: fullText
    Text: View record from DOAJ
    MouseOverText: View record from DOAJ
Header DbId: edsdoj
DbLabel: Directory of Open Access Journals
An: edsdoj.366ef65e5f844a3aaf092de3955f65f9
RelevancyScore: 1047
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 1047.25537109375
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Internal fit and marginal adaptation of all-ceramic implant-supported hybrid abutment crowns with custom-milled screw-channels on Titanium-base: in-vitro study
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Marwa+Wagih+Zaky+Fouad+Fakhr%22">Marwa Wagih Zaky Fouad Fakhr</searchLink><br /><searchLink fieldCode="AR" term="%22Hesham+Alansary%22">Hesham Alansary</searchLink><br /><searchLink fieldCode="AR" term="%22Eman+Ezzat+Youssef+Hassanien%22">Eman Ezzat Youssef Hassanien</searchLink>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: BMC Oral Health, Vol 24, Iss 1, Pp 1-10 (2024)
– Name: Publisher
  Label: Publisher Information
  Group: PubInfo
  Data: BMC, 2024.
– Name: DatePubCY
  Label: Publication Year
  Group: Date
  Data: 2024
– Name: Subset
  Label: Collection
  Group: HoldingsInfo
  Data: LCC:Dentistry
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22CAD%2FCAM%22">CAD/CAM</searchLink><br /><searchLink fieldCode="DE" term="%22Lithium+disilicate%22">Lithium disilicate</searchLink><br /><searchLink fieldCode="DE" term="%22Replica%22">Replica</searchLink><br /><searchLink fieldCode="DE" term="%22Stereomicroscope%22">Stereomicroscope</searchLink><br /><searchLink fieldCode="DE" term="%22Ultra+translucent+zirconia%22">Ultra translucent zirconia</searchLink><br /><searchLink fieldCode="DE" term="%22Dentistry%22">Dentistry</searchLink><br /><searchLink fieldCode="DE" term="%22RK1-715%22">RK1-715</searchLink>
– Name: Abstract
  Label: Description
  Group: Ab
  Data: Abstract Background Advancements in digital dentistry helped in custom-milling screw-channels in implant-supported restorations; however, the fit of these restorations is still unclear especially for contemporary computer aided designing/computer aided manufacturing (CAD/CAM) materials. This study aimed to compare the internal and marginal fit of Ultra translucent multilayered zirconia versus lithium disilicate implant-supported hybrid abutment crowns (HACs) constructed with custom-milled screw-channels on Titanium-base. Materials and methods A total of 24 HACs with custom-milled screw-channels were constructed from lithium disilicate (Group LDS) and Ultra translucent multilayered zirconia (Group UT) using digital workflow (n = 12). The internal and marginal gaps of HACs on their corresponding Titanium-bases were assessed using replica technique and stereomicroscope, respectively. After testing for normality, quantitative data were expressed as mean and standard deviation and compared using independent t-test at a level of significance (P ≤ 0.05). Results There was no statistically significant difference between Group LDS and Group UT in terms of marginal and internal fit. The internal and marginal gaps in both groups were within the accepted values reported in literature. Conclusions UT and LDS HACs with custom-milled screw-channels demonstrated comparable and acceptable internal fit and marginal adaptations to Ti-base, which lied within the range reported in literature.
– Name: TypeDocument
  Label: Document Type
  Group: TypDoc
  Data: article
– Name: Format
  Label: File Description
  Group: SrcInfo
  Data: electronic resource
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: ISSN
  Label: ISSN
  Group: ISSN
  Data: 1472-6831
– Name: NoteTitleSource
  Label: Relation
  Group: SrcInfo
  Data: https://doaj.org/toc/1472-6831
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1186/s12903-024-04810-9
– Name: URL
  Label: Access URL
  Group: URL
  Data: <link linkTarget="URL" linkTerm="https://doaj.org/article/366ef65e5f844a3aaf092de3955f65f9" linkWindow="_blank">https://doaj.org/article/366ef65e5f844a3aaf092de3955f65f9</link>
– Name: AN
  Label: Accession Number
  Group: ID
  Data: edsdoj.366ef65e5f844a3aaf092de3955f65f9
PLink https://login.libproxy.scu.edu/login?url=https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsdoj&AN=edsdoj.366ef65e5f844a3aaf092de3955f65f9
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1186/s12903-024-04810-9
    Languages:
      – Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 10
        StartPage: 1
    Subjects:
      – SubjectFull: CAD/CAM
        Type: general
      – SubjectFull: Lithium disilicate
        Type: general
      – SubjectFull: Replica
        Type: general
      – SubjectFull: Stereomicroscope
        Type: general
      – SubjectFull: Ultra translucent zirconia
        Type: general
      – SubjectFull: Dentistry
        Type: general
      – SubjectFull: RK1-715
        Type: general
    Titles:
      – TitleFull: Internal fit and marginal adaptation of all-ceramic implant-supported hybrid abutment crowns with custom-milled screw-channels on Titanium-base: in-vitro study
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Marwa Wagih Zaky Fouad Fakhr
      – PersonEntity:
          Name:
            NameFull: Hesham Alansary
      – PersonEntity:
          Name:
            NameFull: Eman Ezzat Youssef Hassanien
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 09
              Type: published
              Y: 2024
          Identifiers:
            – Type: issn-print
              Value: 14726831
          Numbering:
            – Type: volume
              Value: 24
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: BMC Oral Health
              Type: main
ResultId 1