Detection of pulmonary nodules in low-dose computed tomography using localized active contours and shape features
Title: | Detection of pulmonary nodules in low-dose computed tomography using localized active contours and shape features |
---|---|
Authors: | Zahra Nadealian, Behzad Nazari, Saeid Sadri, Mohammad Momeni |
Source: | Journal of Medical Signals and Sensors, Vol 7, Iss 4, Pp 203-212 (2017) |
Publisher Information: | Wolters Kluwer Medknow Publications, 2017. |
Publication Year: | 2017 |
Collection: | LCC:Medical technology |
Subject Terms: | Computer-aided detection, computed tomography images, feature extraction, localized active contours, pulmonary nodules, template matching, Medical technology, R855-855.5 |
More Details: | Background: Pulmonary nodules are symptoms of lung cancer. The shape and size of these nodules are used to diagnose lung cancer in computed tomography (CT) images. In the early stages, nodules are very small, and radiologist has to refer to many CT images to diagnose the disease, causing operator mistakes. Image processing algorithms are used as an aid to detect and localize nodules. Methods: In this paper, a novel lung nodules detection scheme is proposed. First, in the preprocessing stage, our algorithm segments two lung lobes to increase processing speed and accuracy. Second, template-matching is applied to detect the suspicious nodule candidates, including both nodules and some blood vessels. Third, the suspicious nodule candidates are segmented by localized active contours. Finally, the false-positive errors produced by vessels are reduced using some two-/three-dimensional geometrical features in three steps. In these steps, the size, long and short diameters and sphericity are used to decrease the false-positive rate. Results: In the first step, some vessels that are parallel to CT cross-plane are identified. In the second step, oblique vessels are detected using shift of center of gravity in two successive slices. In step three, vessels vertical to CT cross-plane are identified. Using these steps, vessels are separated from nodules. Early Lung Cancer Action Project is used as a popular dataset in this work. Conclusions: Our algorithm achieved a sensitivity of 90.1% and a specificity of 92.8%, quite acceptable in comparison to other related works. |
Document Type: | article |
File Description: | electronic resource |
Language: | English |
ISSN: | 2228-7477 |
Relation: | http://www.jmss.mui.ac.ir/article.asp?issn=2228-7477;year=2017;volume=7;issue=4;spage=203;epage=212;aulast=Nadealian; https://doaj.org/toc/2228-7477 |
DOI: | 10.4103/jmss.JMSS_71_16 |
Access URL: | https://doaj.org/article/3102a4b0bff1435c8e171def5f05e6eb |
Accession Number: | edsdoj.3102a4b0bff1435c8e171def5f05e6eb |
Database: | Directory of Open Access Journals |
FullText | Links: – Type: pdflink Url: https://content.ebscohost.com/cds/retrieve?content=AQICAHjPtM4BHU3ZchRwgzYmadcigk49r9CVlbU7V5F6lgH7WwHqZM_Kjs7X9FofDemqIQV4AAAA4TCB3gYJKoZIhvcNAQcGoIHQMIHNAgEAMIHHBgkqhkiG9w0BBwEwHgYJYIZIAWUDBAEuMBEEDONevibJe9sYWM5V4AIBEICBmRhVimpJizNoGrerO79-CZTPAie0-ps607OAq3HYRBQnyHP89S9Rvd9ZmCOhvTe8UTHp13TM2IBU2rtIQSmGVBk-pYE_gowL8BzyoniLejD3wOK5B579m71NEXMhtvOT1k-W5x04as89_vnPr66FCHQ-TSe9P5TLcr629elJsXHZYQ67b71nLJEtnn0XFPvX0pfDibqMV2iJug== Text: Availability: 0 CustomLinks: – Url: https://resolver.ebsco.com/c/xy5jbn/result?sid=EBSCO:edsdoj&genre=article&issn=22287477&ISBN=&volume=7&issue=4&date=20170101&spage=203&pages=203-212&title=Journal of Medical Signals and Sensors&atitle=Detection%20of%20pulmonary%20nodules%20in%20low-dose%20computed%20tomography%20using%20localized%20active%20contours%20and%20shape%20features&aulast=Zahra%20Nadealian&id=DOI:10.4103/jmss.JMSS_71_16 Name: Full Text Finder (for New FTF UI) (s8985755) Category: fullText Text: Find It @ SCU Libraries MouseOverText: Find It @ SCU Libraries – Url: https://doaj.org/article/3102a4b0bff1435c8e171def5f05e6eb Name: EDS - DOAJ (s8985755) Category: fullText Text: View record from DOAJ MouseOverText: View record from DOAJ |
---|---|
Header | DbId: edsdoj DbLabel: Directory of Open Access Journals An: edsdoj.3102a4b0bff1435c8e171def5f05e6eb RelevancyScore: 896 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 896.106628417969 |
IllustrationInfo | |
Items | – Name: Title Label: Title Group: Ti Data: Detection of pulmonary nodules in low-dose computed tomography using localized active contours and shape features – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Zahra+Nadealian%22">Zahra Nadealian</searchLink><br /><searchLink fieldCode="AR" term="%22Behzad+Nazari%22">Behzad Nazari</searchLink><br /><searchLink fieldCode="AR" term="%22Saeid+Sadri%22">Saeid Sadri</searchLink><br /><searchLink fieldCode="AR" term="%22Mohammad+Momeni%22">Mohammad Momeni</searchLink> – Name: TitleSource Label: Source Group: Src Data: Journal of Medical Signals and Sensors, Vol 7, Iss 4, Pp 203-212 (2017) – Name: Publisher Label: Publisher Information Group: PubInfo Data: Wolters Kluwer Medknow Publications, 2017. – Name: DatePubCY Label: Publication Year Group: Date Data: 2017 – Name: Subset Label: Collection Group: HoldingsInfo Data: LCC:Medical technology – Name: Subject Label: Subject Terms Group: Su Data: <searchLink fieldCode="DE" term="%22Computer-aided+detection%22">Computer-aided detection</searchLink><br /><searchLink fieldCode="DE" term="%22computed+tomography+images%22">computed tomography images</searchLink><br /><searchLink fieldCode="DE" term="%22feature+extraction%22">feature extraction</searchLink><br /><searchLink fieldCode="DE" term="%22localized+active+contours%22">localized active contours</searchLink><br /><searchLink fieldCode="DE" term="%22pulmonary+nodules%22">pulmonary nodules</searchLink><br /><searchLink fieldCode="DE" term="%22template+matching%22">template matching</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+technology%22">Medical technology</searchLink><br /><searchLink fieldCode="DE" term="%22R855-855%2E5%22">R855-855.5</searchLink> – Name: Abstract Label: Description Group: Ab Data: Background: Pulmonary nodules are symptoms of lung cancer. The shape and size of these nodules are used to diagnose lung cancer in computed tomography (CT) images. In the early stages, nodules are very small, and radiologist has to refer to many CT images to diagnose the disease, causing operator mistakes. Image processing algorithms are used as an aid to detect and localize nodules. Methods: In this paper, a novel lung nodules detection scheme is proposed. First, in the preprocessing stage, our algorithm segments two lung lobes to increase processing speed and accuracy. Second, template-matching is applied to detect the suspicious nodule candidates, including both nodules and some blood vessels. Third, the suspicious nodule candidates are segmented by localized active contours. Finally, the false-positive errors produced by vessels are reduced using some two-/three-dimensional geometrical features in three steps. In these steps, the size, long and short diameters and sphericity are used to decrease the false-positive rate. Results: In the first step, some vessels that are parallel to CT cross-plane are identified. In the second step, oblique vessels are detected using shift of center of gravity in two successive slices. In step three, vessels vertical to CT cross-plane are identified. Using these steps, vessels are separated from nodules. Early Lung Cancer Action Project is used as a popular dataset in this work. Conclusions: Our algorithm achieved a sensitivity of 90.1% and a specificity of 92.8%, quite acceptable in comparison to other related works. – Name: TypeDocument Label: Document Type Group: TypDoc Data: article – Name: Format Label: File Description Group: SrcInfo Data: electronic resource – Name: Language Label: Language Group: Lang Data: English – Name: ISSN Label: ISSN Group: ISSN Data: 2228-7477 – Name: NoteTitleSource Label: Relation Group: SrcInfo Data: http://www.jmss.mui.ac.ir/article.asp?issn=2228-7477;year=2017;volume=7;issue=4;spage=203;epage=212;aulast=Nadealian; https://doaj.org/toc/2228-7477 – Name: DOI Label: DOI Group: ID Data: 10.4103/jmss.JMSS_71_16 – Name: URL Label: Access URL Group: URL Data: <link linkTarget="URL" linkTerm="https://doaj.org/article/3102a4b0bff1435c8e171def5f05e6eb" linkWindow="_blank">https://doaj.org/article/3102a4b0bff1435c8e171def5f05e6eb</link> – Name: AN Label: Accession Number Group: ID Data: edsdoj.3102a4b0bff1435c8e171def5f05e6eb |
PLink | https://login.libproxy.scu.edu/login?url=https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsdoj&AN=edsdoj.3102a4b0bff1435c8e171def5f05e6eb |
RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.4103/jmss.JMSS_71_16 Languages: – Text: English PhysicalDescription: Pagination: PageCount: 10 StartPage: 203 Subjects: – SubjectFull: Computer-aided detection Type: general – SubjectFull: computed tomography images Type: general – SubjectFull: feature extraction Type: general – SubjectFull: localized active contours Type: general – SubjectFull: pulmonary nodules Type: general – SubjectFull: template matching Type: general – SubjectFull: Medical technology Type: general – SubjectFull: R855-855.5 Type: general Titles: – TitleFull: Detection of pulmonary nodules in low-dose computed tomography using localized active contours and shape features Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Zahra Nadealian – PersonEntity: Name: NameFull: Behzad Nazari – PersonEntity: Name: NameFull: Saeid Sadri – PersonEntity: Name: NameFull: Mohammad Momeni IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Type: published Y: 2017 Identifiers: – Type: issn-print Value: 22287477 Numbering: – Type: volume Value: 7 – Type: issue Value: 4 Titles: – TitleFull: Journal of Medical Signals and Sensors Type: main |
ResultId | 1 |