The Thermal Behavior of a Dual-Function Solar Collector Integrated with Building: An Experimental and Numerical Study on the Air Heating Mode

Bibliographic Details
Title: The Thermal Behavior of a Dual-Function Solar Collector Integrated with Building: An Experimental and Numerical Study on the Air Heating Mode
Authors: Jinwei Ma, Qiang Zhao, Yuehong Su, Jie Ji, Wei He, Zhongting Hu, Tingyong Fang, Haitao Wang
Source: Energies, Vol 11, Iss 9, p 2402 (2018)
Publisher Information: MDPI AG, 2018.
Publication Year: 2018
Collection: LCC:Technology
Subject Terms: flat plate solar collector, dual-function, passive air heating, numerical modeling, Technology
More Details: This paper presented a novel solar collector that can work in air or water heating mode depending on the seasonal requirement. The dual-function solar collector (DFSC) integrated with a building as well as a reference building without the DFSC were built to test thermal behavior in passive air heating mode during winter. The buildings were equipped with an apparatus to control the room temperature. During the testing procedure, experimental study on the DFSC system was carried out under two conditions, where the indoor temperature was controlled and non-controlled. The results showed that the average temperature of the test room was about 3.43 °C higher than that of the reference room under the non-controlled condition. When the room temperature was controlled at 18 °C, the power consumptions of the test room and reference room were 4.322 kWh and 7.796 kWh, respectively. Consequently, the corresponding daily power consumption saved could reach up to around 3.5 kWh. Moreover, a dynamic numerical model on the DFSC along with the building was developed taking the fin effect of the Cu-tubes into account. The numerical results are found to be well consistent with the measured data. A parametric study on with/without Cu-tubes and depth of the air channel was carried out. It is found that the existing Cu-tubes functioning as water heating can enhance the air heating efficiency when the depth of air channel is of a suitable size.
Document Type: article
File Description: electronic resource
Language: English
ISSN: 1996-1073
Relation: http://www.mdpi.com/1996-1073/11/9/2402; https://doaj.org/toc/1996-1073
DOI: 10.3390/en11092402
Access URL: https://doaj.org/article/d131ae7ec6bb430d85e4e831ec9bb267
Accession Number: edsdoj.131ae7ec6bb430d85e4e831ec9bb267
Database: Directory of Open Access Journals
Full text is not displayed to guests.
More Details
ISSN:19961073
DOI:10.3390/en11092402
Published in:Energies
Language:English