Hemosiderin deposition evaluation in hemophilic ankle joints: association between US finding and gradient-recalled echo MR imaging sequence

Bibliographic Details
Title: Hemosiderin deposition evaluation in hemophilic ankle joints: association between US finding and gradient-recalled echo MR imaging sequence
Authors: Marcel Prasetyo, Ariel Elisa Mongan, Novie Amelia Chozie, Joedo Prihartono, Stefanus Imanuel Setiawan
Source: Insights into Imaging, Vol 12, Iss 1, Pp 1-7 (2021)
Publisher Information: SpringerOpen, 2021.
Publication Year: 2021
Collection: LCC:Medical physics. Medical radiology. Nuclear medicine
Subject Terms: Hemosiderin deposition, Hemophilic arthropathy, US, GRE MR imaging, Medical physics. Medical radiology. Nuclear medicine, R895-920
More Details: Abstract Background Repeated bleeding in hemophilic arthropathy (HA) may result in severe degenerative changes and joint destruction. The gradient-recalled echo (GRE) sequence MR is proved to be the best method to detect hemosiderin deposition. However, MR is not widely available in developing countries, including Indonesia. Some studies have proposed ultrasonography (US) as an alternative tool in evaluating hemophilic joint. However, there is still some disagreement on the ability of US to detect hemosiderin deposition. Objective To evaluate the association between US and GRE-sequence MR imaging in detecting hemosiderin deposition in hemophilic ankle joint. Material and methods A total of 102 sites from 17 ankle joints of 11 boys with severe hemophilia A underwent US examination using a high-frequency linear array transducer. GRE-sequence MR examination was performed in sagittal view consistent with the sites scanned by US. Both examinations were performed on the same day, but MR interpretation was performed blindly at different times. The association between US and GRE-sequences in detecting hemosiderin deposition was analyzed using McNemar’s test. Results Statistical analysis showed a significant association (p value
Document Type: article
File Description: electronic resource
Language: English
ISSN: 1869-4101
Relation: https://doaj.org/toc/1869-4101
DOI: 10.1186/s13244-021-01050-1
Access URL: https://doaj.org/article/0d959e3383614fa394e3a6e0a5561d71
Accession Number: edsdoj.0d959e3383614fa394e3a6e0a5561d71
Database: Directory of Open Access Journals
Full text is not displayed to guests.
FullText Links:
  – Type: pdflink
    Url: https://content.ebscohost.com/cds/retrieve?content=AQICAHjPtM4BHU3ZchRwgzYmadcigk49r9CVlbU7V5F6lgH7WwFI7_GqqWf1GyFpeg5rKbjrAAAA4jCB3wYJKoZIhvcNAQcGoIHRMIHOAgEAMIHIBgkqhkiG9w0BBwEwHgYJYIZIAWUDBAEuMBEEDAvKf8U4YkUrQm8p9gIBEICBmgbEDQLeJQxARUcO8hvGOkt4Y4772eIoQjmDSKwR__QmUJ2Sp3FJdU26gpEqyVZU2_usjq4IxQtwNjC6hXGL-Asa22FcUVxcvd-kUAzU85nn33_pZv7NLtpkg44smSHb0p93DEBDk3WSLJE_4_w27-9K8fzpItX6JxeFPO3-6xsTHHJt9dmEUkurcRpXk6IL2FW8tVueH8iJsYU=
Text:
  Availability: 1
  Value: <anid>AN0152274649;[b617]27jul.21;2021Sep07.02:21;v2.2.500</anid> <title id="AN0152274649-1">Hemosiderin deposition evaluation in hemophilic ankle joints: association between US finding and gradient-recalled echo MR imaging sequence </title> <p>Background: Repeated bleeding in hemophilic arthropathy (HA) may result in severe degenerative changes and joint destruction. The gradient-recalled echo (GRE) sequence MR is proved to be the best method to detect hemosiderin deposition. However, MR is not widely available in developing countries, including Indonesia. Some studies have proposed ultrasonography (US) as an alternative tool in evaluating hemophilic joint. However, there is still some disagreement on the ability of US to detect hemosiderin deposition. Objective: To evaluate the association between US and GRE-sequence MR imaging in detecting hemosiderin deposition in hemophilic ankle joint. Material and methods: A total of 102 sites from 17 ankle joints of 11 boys with severe hemophilia A underwent US examination using a high-frequency linear array transducer. GRE-sequence MR examination was performed in sagittal view consistent with the sites scanned by US. Both examinations were performed on the same day, but MR interpretation was performed blindly at different times. The association between US and GRE-sequences in detecting hemosiderin deposition was analyzed using McNemar's test. Results: Statistical analysis showed a significant association (p value < 0.001) between US and GRE MR in detecting hemosiderin deposition, but the association is weak (R = 0.26). Sensitivity and specificity of US for detecting hemosiderin deposition were 46.84% (95%CI: 35.51–58.40) and 95.65% (95%CI: 78.05–99.89), respectively, with positive predictive value 97.37% (95%CI: 84.29–99.61), negative predictive value 34.38% (95%CI: 29.50–39.60) and accuracy 57.84% (95%CI: 47.66–67.56). Conclusion: There was a weak association between US and GRE-sequences in detecting hemosiderin deposition of hemophilic ankle joint. ​​</p> <p>Keywords: Hemosiderin deposition; Hemophilic arthropathy; US; GRE MR imaging</p> <hd id="AN0152274649-2">Key points</hd> <p></p> <ulist> <item> US can evaluate hemosiderin better if there are a large amount and heterogeneous echotexture of hemosiderin deposition.</item> <p></p> <item> There is a weak association between US and GRE MR in detecting hemosiderin deposition.</item> <p></p> <item> Hemosiderin deposition could be easier to be identified in the anterior and posterior recess of ankle joint.</item> </ulist> <hd id="AN0152274649-3">Introduction</hd> <p>Hemophilic arthropathy (HA) is the most common clinical manifestation of hemophilia. Recurrent bleeding causes synovial hypertrophy, hemosiderin deposition, cartilage destruction, and changes in the structure of subchondral bone. Hemosiderin deposition can stimulate further synovial hypertrophy and inflammation. As a result, joints become painful and could lose their physiological function which further potentially causes disabilities [[<reflink idref="bib1" id="ref1">1</reflink>]–[<reflink idref="bib4" id="ref2">4</reflink>]]. Magnetic Resonance (MR) imaging is superior to other imaging modality in detecting soft tissue changes, such as synovial hypertrophy, hemarthrosis, joint effusion, cartilage defect, and changes in bone structure [[<reflink idref="bib5" id="ref3">5</reflink>]–[<reflink idref="bib7" id="ref4">7</reflink>]]. The gradient-recalled echo (GRE) MR imaging sequence is regarded as a sensitive method in evaluating hemosiderin deposition [[<reflink idref="bib8" id="ref5">8</reflink>]]. However, MR imaging is not the first choice of imaging considering the cost, need of sedation, time-consuming, limited access in developing countries, and inability to perform imaging in multiple joints at the same time [[<reflink idref="bib9" id="ref6">9</reflink>]].</p> <p>Many studies have proposed the use of US in evaluating HA [[<reflink idref="bib4" id="ref7">4</reflink>]–[<reflink idref="bib8" id="ref8">8</reflink>], [<reflink idref="bib10" id="ref9">10</reflink>]–[<reflink idref="bib17" id="ref10">17</reflink>]]. However, there was some disagreement regarding US ability in detecting hemosiderin deposition in hemophilic joint. Doria et al. [[<reflink idref="bib14" id="ref11">14</reflink>]] reported the sensitivity and specificity of US for hemosiderin detection are 100% and 67%, respectively, and it was shown as hypoechoic structures. Hemosiderin deposition outside of the synovium is also reported. According to Martinoli et al. [[<reflink idref="bib15" id="ref12">15</reflink>]], hemosiderin is embedded inside the synovium and does not accumulate in joint space which makes misleading interpretation of US findings on hemosiderin deposition. Different opinions on the echogenicity of hemosiderin are also noted, as Melchiorre et al. [[<reflink idref="bib4" id="ref13">4</reflink>]] defined hemosiderin deposition as a diffuse hyperechoic area. This study aims to evaluate US ability to identify hemosiderin deposition at the same anatomical sites of hemophilic ankle joint, in comparison with GRE-sequence MR imaging.</p> <hd id="AN0152274649-4">Materials and methods</hd> <p>A cross-sectional study was performed on ankle joints of boys aged 7–18 years old with severe hemophilia A and no history of inhibitor. Ankle joints examined were considered as target joint with HEAD-US score ≥ 6. Each child participant's guardian was given written informed consent and the patient data were kept anonymous and confidential. This study was conducted in the Cipto Mangunkusumo National General Hospital (RSUPN-CM), Jakarta. Ankle US was performed in 6 sites, based on the method proposed by Zukotynski et al. [[<reflink idref="bib16" id="ref14">16</reflink>]] with some modification. In this study, the 6 sites were marked as P1–P6. Anterior central scan (P1) was performed with transducer placed above middle area of the ankle and parallel to the long axis of the leg, anteromedial (P2) landmark was anterior aspect of medial malleolus, and anterolateral (P3) landmark was anterior aspect of lateral malleolus. Anterior scan (P1-P3) was performed with subject in supine position, while posterior scan (P4-P6) in prone position. The posterior central scan (P4) was performed when transducer was placed above the Achilles tendon parallel to tendon axis, posteromedial (P5) landmark was posterior aspect of medial malleolus, and posterolateral (P6) landmark was posterior aspect of lateral malleolus (Fig. 1). Subjects with ankle joint deformity and history of synovectomy were excluded. Ankle US was performed in longitudinal view on the P1–P6 locations, using Philips Affinity 70® US machine with a 12-MHz linear array transducer. Positive US finding for hemosiderin is defined as a hypoechoic structure with indistinct border, either within the synovial cavity or embedded within synovial wall.</p> <p>Graph: Fig. 1 Sites observed for each ankle. i Axial view; ii sagittal view; a anterior approach; b posterior approach: mid ankle (P1), anterior to medial malleolus (P2), anterior to the lateral malleolus (P3), midline (P4), posterior to medial malleolus (P5), and posterior to the lateral malleolus (P6)</p> <p>Ankle MR was performed using 1.5 Tesla GE Optima® machine. Patient was positioned in supine position, and the ankle was scanned using dedicated RF coil for ankle with the single-channel 1.5 HD T/R Quad Extremity coil. Sequence performed is gradient-recalled echo T2* in true sagittal section; repetition time 674 ms, echo time 14,5 ms, flip angle 30°, slice thickness 4 mm, a field of view 18 cm, matrix 256 × 192. Besides, T2 fat suppression routine sequence in the sagittal section was also performed. Positive MR finding for hemosiderin is defined as a hypointense blooming artifact on GRE sequence, located at the P1-P6 sites consistent with US scan locations.</p> <p>US and MR scans were performed on the same day. US results were interpreted directly during scanning, while MR results were interpreted blindly approximately 3 weeks after scanning. US and MR interpretation were performed by a musculoskeletal radiologist with at least 10-years of experience in musculoskeletal ultrasound, who was also a member of Multidisciplinary Hemophilia Management Team of Cipto Mangunkusumo General Hospital, Jakarta. False negative echogenicity features of US examination, including isoechoic and hyperechoic findings, but positive minimal hemosiderin deposition in MR were recorded descriptively and further discussed. Statistical analysis using McNemar's test was performed using SPSS 20 to measure the association in detecting hemosiderin between US and MR. Sensitivity and specificity analyses were also done to assess the capability of US in detecting hemosiderin compared to MR. Cohen's Kappa R value was also calculated to show the concordance between US and MR findings. The Kappa R value was further categorized into > 0.75 as 'strong interobserver agreement'; 0.4–0.75 as 'moderate interobserver agreement'; < 0.4 as 'weak interobserver agreement.'</p> <hd id="AN0152274649-5">Results</hd> <p>A total of 102 sites from 17 ankle joints obtained from 11 boys with characteristics described further in Table 1. US and MR showed a weak association in detecting hemosiderin (<emph>R</emph> = 0.26, <emph>p</emph> < 0.001) (Table 2). Sensitivity and specificity of US for detecting hemosiderin deposition were 46.84% (95%CI: 35.51–58.40) and 95.65% (95%CI: 78.05–99.89), respectively, with positive predictive value 97.37% (95%CI: 84.29–99.61), negative predictive value 34.38% (95%CI: 29.50–39.60) and accuracy 57.84% (95%CI: 47.66–67.56).</p> <p>Table 1 Characteristics of subjects</p> <p> <ephtml> <table frame="hsides" rules="groups"><thead><tr><th align="left"><p>Subject characteristics</p></th><th align="left"><p><italic>N</italic> (%)</p></th></tr></thead><tbody><tr><td align="left" colspan="2"><p><italic>Age groups</italic></p></td></tr><tr><td align="left"><p> < 10 years old</p></td><td align="left"><p>4 (36.4)</p></td></tr><tr><td align="left"><p> > 10 years old</p></td><td align="left"><p>7 (63.6)</p></td></tr><tr><td align="left" colspan="2"><p><italic>Affected ankle joint</italic></p></td></tr><tr><td align="left"><p>Unilateral (right ankle joint)</p></td><td align="left"><p>3 (27.3)</p></td></tr><tr><td align="left"><p>Unilateral (left ankle joint)</p></td><td align="left"><p>2 (18.2)</p></td></tr><tr><td align="left"><p>Bilateral</p></td><td align="left"><p>6 (36.4)</p></td></tr><tr><td align="left" colspan="2"><p><italic>HEAD-US score of the right ankle joint</italic></p></td></tr><tr><td align="left"><p>HEAD-US score: 6</p></td><td align="left"><p>4 (36.4)</p></td></tr><tr><td align="left"><p>HEAD-US score: 7</p></td><td align="left"><p>3 (27.3)</p></td></tr><tr><td align="left"><p>Missing</p></td><td align="left"><p>4 (36.4)</p></td></tr><tr><td align="left" colspan="2"><p><italic>HEAD-US score of the left ankle joint</italic></p></td></tr><tr><td align="left"><p>HEAD-US score: 6</p></td><td align="left"><p>2 (18.2)</p></td></tr><tr><td align="left"><p>HEAD-US score: 7</p></td><td align="left"><p>4 (36.4)</p></td></tr><tr><td align="left"><p>HEAD-US score: 8</p></td><td align="left"><p>2 (18.2)</p></td></tr><tr><td align="left"><p>Missing</p></td><td align="left"><p>3 (27.3)</p></td></tr></tbody></table> </ephtml> </p> <p>Table 2 Association between US and MRI results in detecting hemosiderin deposition</p> <p> <ephtml> <table frame="hsides" rules="groups"><thead><tr><th align="left" rowspan="2"><p>Hemosiderin deposition finding in the US</p></th><th align="left" colspan="2"><p>Hemosiderin deposition in the GRE MR imaging sequences</p></th><th align="left" rowspan="2"><p>Total</p><p><italic>N</italic></p></th><th align="left" rowspan="2"><p><italic>p</italic> value</p></th></tr><tr><th align="left"><p>Positive</p><p><italic>N</italic> (%)</p></th><th align="left"><p>Negative</p><p><italic>N</italic> (%)</p></th></tr></thead><tbody><tr><td align="left"><p>Positive</p></td><td align="left"><p>37 (97.37)</p></td><td align="left"><p>1 (2.63)</p></td><td align="left"><p>38</p></td><td align="left" rowspan="3"><p> < 0.05</p></td></tr><tr><td align="left"><p>Negative</p></td><td align="left"><p>42 (65.63)</p></td><td align="left"><p>22 (34.37)</p></td><td align="left"><p>64</p></td></tr><tr><td align="left"><p>Total</p></td><td align="left"><p>79 (77.45)</p></td><td align="left"><p>23 (22.55)</p></td><td align="left"><p>102</p></td></tr></tbody></table> </ephtml> </p> <p>Similar locations of hemosiderin found on US and MR are following: 12 (32.43%) samples in P4 (Fig. 2); 9 (24.32%) samples in P1; 5 (13.51%) samples in P3, P5 and P6; and 1 (2.70%) sample in P2 (Fig. 3). Negative US findings but positive MR were found in following locations: 12 (28.57%) samples in P2, 9 (21.43%) samples in P6, 8 (19.05%) samples in P3, 7 (16.67%) samples in P5, 5 (11.90%) samples in P1, and 1 (2.38%) sample in P4.</p> <p>Graph: Fig. 2 a US finding in P4 location on right ankle shows the hypoechoic area (thin yellow arrow) with hypertrophic synovium with the intermediate-echogenicity area (thick blue arrow) that was moderately compressible (b). c The MR study in the same location confirms hemosiderin</p> <p>Graph: Fig. 3 a US finding in P2 location (anterior-medial) shows a hypoechoic area (red box) inferior to the medial malleolus, consistent with hemosiderin on MR comparison (b)</p> <p>Based on positive MR of hemosiderin deposition (<emph>n</emph> = 79), US echogenicity was mostly hypoechoic on 73 samples (92.0%), while only 4 samples (5.0%) were found isoechoic and 2 samples (3.0%) hyperechoic.</p> <hd id="AN0152274649-6">Discussion</hd> <p>There was a statistically significant difference in results between US and MR imaging in detecting hemosiderin deposition in hemophilic joints and the concordance value is almost equal with discordance value. US also has low sensitivity with relatively low negative predictive value in detecting hemosiderin deposition, resulting from three main factors: the amount of hemosiderin, the echotexture of hemosiderin, and the location of sampling. These three factors were based on descriptive data distribution found in this study. Non-corresponding data between MR and US were found. MR could detect minimal hemosiderin observed as dots, which is not detectable and hard to be visualized by US. This minimal hemosiderin deposition could be easily found in MR imaging, but in US, it is difficult to be differentiated with the surrounding structures such as synovial thickening, cartilage, and fat pads which lead to misinterpretation of the structure as non-hemosiderin, similar to previous studies by Martinoli et al<emph>.</emph> [[<reflink idref="bib15" id="ref15">15</reflink>]], Zukotynski et al<emph>.</emph> [[<reflink idref="bib16" id="ref16">16</reflink>]] and Prasetyo et al<emph>.</emph> [[<reflink idref="bib17" id="ref17">17</reflink>]].</p> <p>The second factor is the echotexture phenomenon in this study. Hemosiderin echotexture distribution was dominant to be heterogeneous echotexture. In this study, homogenous hypoechoic echotexture finding was mostly not associated with MR results due to its similarity to synovial thickening, while the heterogeneous hypoechoic echotexture finding tends to associate with MR results. Based on these results, in an area with relatively higher echogenicity, it is observed that hemosiderin deposition which characterized by a hypoechoic area could create a heterogeneous characteristic. A study by Doria et al. [[<reflink idref="bib14" id="ref18">14</reflink>]] also found that synovium has a wide echotexture and showed a varying level of hemosiderin deposition. However, that study demonstrated a high sensitivity (> 92%) of US in detecting hemosiderin deposition compared to MR findings, a much higher sensitivity compared to this study (46.84% (95%CI: 35.51–58.40)). This could be explained by the methodology used in this study which compared data from MR and US at the same anatomical level, not as a whole ankle. Furthermore, the number of joint bleeding and a history of bleeding recurrences can affect the echogenicity of hemosiderin deposition.</p> <p>The third factor that affected hemosiderin detection in US is the sampling location. The location with the highest positive results in detecting hemosiderin deposition using both US and MR were P4 location (central-posterior) and P1 (central-anterior) since these locations are sensitive in detecting joint effusion fluid, which could push a high amount of fat pad. [[<reflink idref="bib18" id="ref19">18</reflink>]] Furthermore, the probe could be easily placed parallel to long axis of tibial bone (anterior side) and calcaneal tendon (posterior side), thus creating minimal artifact and anisotropy. However, the bulging of malleolus and the different size of each patient's ankle, to assess the lateral and medial part, were causing probe surface to not fully adhere to the skin surface. This factor caused the observed area to not be optimally visualized, especially in deeper areas<subs>,</subs> which created shadow refraction artifacts and anisotropy. These technical issues need to be considered to minimalize artifacts which would later affect the detection and identification of hemosiderin deposition and may be prevented by using more gel on the gap between the probe and skin or using a smaller probe (hockey stick).</p> <p>All positive joint hemosiderin deposition on both modalities was accompanied by severe synovial hypertrophy. This is related to HA pathophysiology and cycle, the process of hemarthrosis-synovitis-hemarthrosis, and could be concluded that hemosiderin tends to be detected at conditions with severe synovial thickening [[<reflink idref="bib3" id="ref20">3</reflink>]].</p> <p>The hemosiderin deposition is mostly found as hypoechoic. Only a small number of samples were found to be isoechoic and hyperechoic shown in MR imaging as small focal spots of hemosiderin deposition (Fig. 4). These echogenicity features resulted as negative interpretation of hemosiderin deposition in US because they were hard to be differentiated from the surrounding structures. Thus, the ability of US in detecting hemosiderin might depend on the severity of hemosiderin content.</p> <p>Graph: Fig. 4 US examination at P1 location on the left ankle (a) showed synovial thickening as confirmed by MRI (b). Minimal hemosiderin (red box) is difficult to visualize on the US due to its closed proximity to the thickened synovium</p> <p>The limitation of this study is that hypoechoic structure seen in US as hemosiderin could not be confirmed directly because a histopathology examination was not performed. Besides, both US examination and the interpretation of the GRE sequences were performed by a single musculoskeletal radiologist. This study does not assess US performance to detect hemosiderin for one patient, but for one anatomical level, hence low sensitivity of ultrasound reported in this study. However, this study could highlight the best sagittal transducer positions for hemosiderin detection in ankle joint, which is anterior and posterior recess.</p> <hd id="AN0152274649-7">Conclusion</hd> <p>There is a weak association between US and MR imaging in detecting hemosiderin deposition. The sensitivity and specificity of US for detecting hemosiderin deposition were 46.8% and 95.7%, respectively, with the accuracy of 57.8%. Hemosiderin deposition in US is characterized as a hypoechoic structure relative to the synovium, which is easier to be identified in thick hypertrophic synovium, especially in the anterior and posterior recess of ankle joint.</p> <hd id="AN0152274649-8">Acknowledgements</hd> <p>The authors wish to thank the Department of Radiology, Faculty of Medicine Universitas Indonesia for the contribution. We also thank Dr. Cipto Mangunkusumo National Central General Hospital for the research permission approval.</p> <hd id="AN0152274649-9">Authors' contributions</hd> <p>MP and AEM were involved in conceptualization and design. AEM and NAC were involved in investigation. MP and NAC were involved in methodology. MP and SIS were involved in writing—reviewing and editing. MP, NAC and JP were involved in supervision. AEM and SIS were involved in data curation. SIS and JP performed software. SIS and MP were involved in project administration. JP performed formal analysis. MP was involved in visualization. AEM was involved in writing—original draft preparation. All authors read and approved the final manuscript.</p> <hd id="AN0152274649-10">Funding</hd> <p>The author(s) received no financial support for the research, authorship, and/or publication of this article.</p> <hd id="AN0152274649-11">Availability of data and materials</hd> <p>Supporting data were available for review by the corresponding author.</p> <hd id="AN0152274649-12">Declarations</hd> <p></p> <hd id="AN0152274649-13">Ethics approval and consent to participate</hd> <p>This study was conducted with approval of the Research Ethics Committee of the Faculty of Medicine Universitas Indonesia Number 277/UN2.F1/ETIK/2017. Data used in this study were kept anonymously and confidential and each of included subjects was given a written informed consent.</p> <hd id="AN0152274649-14">Consent for publication</hd> <p>Written informed consent was obtained from the patient's guardian for publication of this study and the patient's identity was being kept anonymous.</p> <hd id="AN0152274649-15">Competing interests</hd> <p>The authors declare that they have no competing interests.</p> <hd id="AN0152274649-16">Abbreviations</hd> <p></p> <p>• GRE</p> <p></p> <ulist> <item> Gradient-recalled echo</item> <p></p> </ulist> <p>• HA</p> <p></p> <ulist> <item> Hemophilic arthropathy</item> <p></p> </ulist> <p>• HEAD-US</p> <p></p> <ulist> <item> Hemophilia Early Arthropathy Detection with Ultrasound</item> <p></p> </ulist> <p>• MR</p> <p></p> <ulist> <item> Magnetic Resonance</item> <p></p> </ulist> <p>• US</p> <p></p> <ulist> <item> Ultrasonography</item> </ulist> <hd id="AN0152274649-17">Publisher's Note</hd> <p>Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.</p> <ref id="AN0152274649-18"> <title> References </title> <blist> <bibl id="bib1" idref="ref1" type="bt">1</bibl> <bibtext> Kraft J, Blanchette V, Babyn P. Magnetic resonance imaging and joint outcomes in boys with severe hemophilia A treated with tailored primary prophylaxis in Canada. J Thromb Haemost. 2012; 10; 12: 2494-2502. 1:CAS:528:DC%2BC3sXhsFCjsb4%3D. 10.1111/jth.12025</bibtext> </blist> <blist> <bibl id="bib2" type="bt">2</bibl> <bibtext> Maclachlan J, Gough-Palmer A, Hargunani R, Farrant J, Holloway B. Haemophilia imaging: a review. Skeletal Radiol. 2009; 38; 10: 949-957. 10.1007/s00256-008-0586-5</bibtext> </blist> <blist> <bibl id="bib3" idref="ref20" type="bt">3</bibl> <bibtext> Cross S, Vaidya S, Fotiadis N. Hemophilic arthropathy: a review of imaging and staging. Semin Ultrasound CT MR. 2013; 34; 6: 516-524. 10.1053/j.sult.2013.05.007</bibtext> </blist> <blist> <bibl id="bib4" idref="ref2" type="bt">4</bibl> <bibtext> Melchiorre D, Linari S, Innocenti M. Ultrasound detects joint damage and bleeding in haemophilic arthropathy: a proposal of a score. Haemophilia. 2011; 17; 1: 112-117. 1:STN:280:DC%2BC3M%2Fot1CrsA%3D%3D. 10.1111/j.1365-2516.2010.02380.x</bibtext> </blist> <blist> <bibl id="bib5" idref="ref3" type="bt">5</bibl> <bibtext> Querol F, Rodriguez-Merchan EC. The role of ultrasonography in the diagnosis of the musculo-skeletal problems of haemophilia. Haemophilia. 2012; 18; 3: e215-e226. 1:STN:280:DC%2BC38zntVCgsQ%3D%3D. 10.1111/j.1365-2516.2011.02680.x</bibtext> </blist> <blist> <bibl id="bib6" type="bt">6</bibl> <bibtext> Foppen W, van der Schaaf IC, Fischer K. Value of routine ultrasound in detecting early joint changes in children with haemophilia using the 'Haemophilia Early Arthropathy Detection with UltraSound' protocol. Haemophilia. 2016; 22; 1: 121-125. 1:STN:280:DC%2BC28%2FotlOjtw%3D%3D. 10.1111/hae.12769</bibtext> </blist> <blist> <bibl id="bib7" idref="ref4" type="bt">7</bibl> <bibtext> Muça-Perja M, Riva S, Grochowska B, Mangiafico L, Mago D, Gringeri A. Ultrasonography of haemophilic arthropathy. Haemophilia. 2012; 18; 3: 364-368. 10.1111/j.1365-2516.2011.02672.x. 21999202</bibtext> </blist> <blist> <bibl id="bib8" idref="ref5" type="bt">8</bibl> <bibtext> Doria AS. State-of-the-art imaging techniques for the evaluation of haemophilic arthropathy: present and future. Haemophilia. 2010; 16; Suppl 5: 107-114. 10.1111/j.1365-2516.2010.02307.x</bibtext> </blist> <blist> <bibl id="bib9" idref="ref6" type="bt">9</bibl> <bibtext> Wyseure T, Mosnier LO, von Drygalski A. Advances and challenges in hemophilic arthropathy. Semin Hematol. 2016; 53; 1: 10-19. 1:CAS:528:DC%2BC28XhtlSntb4%3D. 10.1053/j.seminhematol.2015.10.005</bibtext> </blist> <blist> <bibtext> Martinoli C, Della Casa Alberighi O, Di Minno G. Development and definition of a simplified scanning procedure and scoring method for Haemophilia Early Arthropathy Detection with Ultrasound (HEAD-US). Thromb Haemost. 2013; 109; 6: 1170-1179. 1:CAS:528:DC%2BC3sXpsFGqurs%3D. 10.1160/TH12-11-0874</bibtext> </blist> <blist> <bibtext> Xavier F, Zhang N, Mohanta A. Sonography for assessment of elbows in hemophilic children: a systematic protocol. Rheumatol Curr Res. 2012; 4: 2161-1149</bibtext> </blist> <blist> <bibtext> Prasetyo M, Moniqa R, Tulaar A, Prihartono J, Setiawan SI. Correlation between Hemophilia Early Arthropathy Detection with Ultrasound (HEAD-US) score and Hemophilia Joint Health Score (HJHS) in patients with hemophilic arthropathy. PLoS One. 2021; 16; 4. 1:CAS:528:DC%2BB3MXovVGksr8%3D. 10.1371/journal.pone.0248952. 33826621. 8026024</bibtext> </blist> <blist> <bibtext> Zhang C, Zhang J, Xu J, Guo YBS, Wang G, Yang L. Musculoskeletal ultrasonography for arthropathy assessment in patients with hemophilia. Medicine (Baltimore). 2018; 97; 46. 10.1097/MD.0000000000013230</bibtext> </blist> <blist> <bibtext> Doria AS, Keshava SN, Mohanta A. Diagnostic accuracy of ultrasound for assessment of hemophilic arthropathy: MRI correlation. AJR Am J Roentgenol. 2015; 204; 3: W336-W347. 10.2214/AJR.14.12501</bibtext> </blist> <blist> <bibtext> Martinoli C, Di Minno MN, Pasta G, Tagliafico A. Haemosiderin detection with ultrasound: reality or myth?. AJR Am J Roentgenol. 2016; 206; 1: W30. 10.2214/AJR.15.14981</bibtext> </blist> <blist> <bibtext> Zukotynski K, Jarrin J, Babyn PS. Sonography for assessment of haemophilic arthropathy in children: a systematic protocol. Haemophilia. 2007; 13; 3: 293-304. 1:STN:280:DC%2BD2s3oslOrtg%3D%3D. 10.1111/j.1365-2516.2006.01414.x</bibtext> </blist> <blist> <bibtext> Prasetyo M, Gatot D, Tulaar ABM. Association between ultrasonographic score and magnetic resonance imaging score in early detection of knee haemophilic arthropathy. J Phys Conf Ser. 2018; 1073; 4: 042022. 10.1088/1742-6596/1073/4/042022</bibtext> </blist> <blist> <bibtext> Qasim Z, Naseem L, Asif N, Hassan K. Haemophilia; pattern of clinical presentation and disease severity. Int J Pathol. 2013; 11: 58-63</bibtext> </blist> </ref> <aug> <p>By Marcel Prasetyo; Ariel Elisa Mongan; Novie Amelia Chozie; Joedo Prihartono and Stefanus Imanuel Setiawan</p> <p>Reported by Author; Author; Author; Author; Author</p> </aug> <nolink nlid="nl1" bibid="bib10" firstref="ref9"></nolink> <nolink nlid="nl2" bibid="bib17" firstref="ref10"></nolink> <nolink nlid="nl3" bibid="bib14" firstref="ref11"></nolink> <nolink nlid="nl4" bibid="bib15" firstref="ref12"></nolink> <nolink nlid="nl5" bibid="bib16" firstref="ref14"></nolink> <nolink nlid="nl6" bibid="bib18" firstref="ref19"></nolink>
CustomLinks:
  – Url: https://resolver.ebsco.com/c/xy5jbn/result?sid=EBSCO:edsdoj&genre=article&issn=18694101&ISBN=&volume=12&issue=1&date=20210701&spage=1&pages=1-7&title=Insights into Imaging&atitle=Hemosiderin%20deposition%20evaluation%20in%20hemophilic%20ankle%20joints%3A%20association%20between%20US%20finding%20and%20gradient-recalled%20echo%20MR%20imaging%20sequence&aulast=Marcel%20Prasetyo&id=DOI:10.1186/s13244-021-01050-1
    Name: Full Text Finder (for New FTF UI) (s8985755)
    Category: fullText
    Text: Find It @ SCU Libraries
    MouseOverText: Find It @ SCU Libraries
  – Url: https://doaj.org/article/0d959e3383614fa394e3a6e0a5561d71
    Name: EDS - DOAJ (s8985755)
    Category: fullText
    Text: View record from DOAJ
    MouseOverText: View record from DOAJ
Header DbId: edsdoj
DbLabel: Directory of Open Access Journals
An: edsdoj.0d959e3383614fa394e3a6e0a5561d71
RelevancyScore: 952
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 951.900207519531
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Hemosiderin deposition evaluation in hemophilic ankle joints: association between US finding and gradient-recalled echo MR imaging sequence
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Marcel+Prasetyo%22">Marcel Prasetyo</searchLink><br /><searchLink fieldCode="AR" term="%22Ariel+Elisa+Mongan%22">Ariel Elisa Mongan</searchLink><br /><searchLink fieldCode="AR" term="%22Novie+Amelia+Chozie%22">Novie Amelia Chozie</searchLink><br /><searchLink fieldCode="AR" term="%22Joedo+Prihartono%22">Joedo Prihartono</searchLink><br /><searchLink fieldCode="AR" term="%22Stefanus+Imanuel+Setiawan%22">Stefanus Imanuel Setiawan</searchLink>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: Insights into Imaging, Vol 12, Iss 1, Pp 1-7 (2021)
– Name: Publisher
  Label: Publisher Information
  Group: PubInfo
  Data: SpringerOpen, 2021.
– Name: DatePubCY
  Label: Publication Year
  Group: Date
  Data: 2021
– Name: Subset
  Label: Collection
  Group: HoldingsInfo
  Data: LCC:Medical physics. Medical radiology. Nuclear medicine
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Hemosiderin+deposition%22">Hemosiderin deposition</searchLink><br /><searchLink fieldCode="DE" term="%22Hemophilic+arthropathy%22">Hemophilic arthropathy</searchLink><br /><searchLink fieldCode="DE" term="%22US%22">US</searchLink><br /><searchLink fieldCode="DE" term="%22GRE+MR+imaging%22">GRE MR imaging</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+physics%2E+Medical+radiology%2E+Nuclear+medicine%22">Medical physics. Medical radiology. Nuclear medicine</searchLink><br /><searchLink fieldCode="DE" term="%22R895-920%22">R895-920</searchLink>
– Name: Abstract
  Label: Description
  Group: Ab
  Data: Abstract Background Repeated bleeding in hemophilic arthropathy (HA) may result in severe degenerative changes and joint destruction. The gradient-recalled echo (GRE) sequence MR is proved to be the best method to detect hemosiderin deposition. However, MR is not widely available in developing countries, including Indonesia. Some studies have proposed ultrasonography (US) as an alternative tool in evaluating hemophilic joint. However, there is still some disagreement on the ability of US to detect hemosiderin deposition. Objective To evaluate the association between US and GRE-sequence MR imaging in detecting hemosiderin deposition in hemophilic ankle joint. Material and methods A total of 102 sites from 17 ankle joints of 11 boys with severe hemophilia A underwent US examination using a high-frequency linear array transducer. GRE-sequence MR examination was performed in sagittal view consistent with the sites scanned by US. Both examinations were performed on the same day, but MR interpretation was performed blindly at different times. The association between US and GRE-sequences in detecting hemosiderin deposition was analyzed using McNemar’s test. Results Statistical analysis showed a significant association (p value
– Name: TypeDocument
  Label: Document Type
  Group: TypDoc
  Data: article
– Name: Format
  Label: File Description
  Group: SrcInfo
  Data: electronic resource
– Name: Language
  Label: Language
  Group: Lang
  Data: English
– Name: ISSN
  Label: ISSN
  Group: ISSN
  Data: 1869-4101
– Name: NoteTitleSource
  Label: Relation
  Group: SrcInfo
  Data: https://doaj.org/toc/1869-4101
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.1186/s13244-021-01050-1
– Name: URL
  Label: Access URL
  Group: URL
  Data: <link linkTarget="URL" linkTerm="https://doaj.org/article/0d959e3383614fa394e3a6e0a5561d71" linkWindow="_blank">https://doaj.org/article/0d959e3383614fa394e3a6e0a5561d71</link>
– Name: AN
  Label: Accession Number
  Group: ID
  Data: edsdoj.0d959e3383614fa394e3a6e0a5561d71
PLink https://login.libproxy.scu.edu/login?url=https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsdoj&AN=edsdoj.0d959e3383614fa394e3a6e0a5561d71
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1186/s13244-021-01050-1
    Languages:
      – Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 1
    Subjects:
      – SubjectFull: Hemosiderin deposition
        Type: general
      – SubjectFull: Hemophilic arthropathy
        Type: general
      – SubjectFull: US
        Type: general
      – SubjectFull: GRE MR imaging
        Type: general
      – SubjectFull: Medical physics. Medical radiology. Nuclear medicine
        Type: general
      – SubjectFull: R895-920
        Type: general
    Titles:
      – TitleFull: Hemosiderin deposition evaluation in hemophilic ankle joints: association between US finding and gradient-recalled echo MR imaging sequence
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Marcel Prasetyo
      – PersonEntity:
          Name:
            NameFull: Ariel Elisa Mongan
      – PersonEntity:
          Name:
            NameFull: Novie Amelia Chozie
      – PersonEntity:
          Name:
            NameFull: Joedo Prihartono
      – PersonEntity:
          Name:
            NameFull: Stefanus Imanuel Setiawan
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 07
              Type: published
              Y: 2021
          Identifiers:
            – Type: issn-print
              Value: 18694101
          Numbering:
            – Type: volume
              Value: 12
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Insights into Imaging
              Type: main
ResultId 1